Configuration and Firmware Update
19
NI-3101-SIG Signature Series NetLinx Integrated Controller
2.
Select the Change System selection box from the System to Change section.
3.
Enter both the current and new system address values.
4.
Click the Change Device/System Number button. This configures the Master to accept the new value
and incorporate the information. The system information in the OnLine Tree tab of the Workspace window
refreshes and then displays the new information.
5.
Click Done to close the Device Addressing dialog and return to the main program.
6.
Click Reboot (from the Tools > Reboot the Master Controller dialog) and wait for the System Master
to reboot. The STATUS and OUTPUT LEDs should begin to alternately blink during the incorporation.
Wait until the STATUS LED is the only LED to blink.
7.
Press Done once until the Master Reboot Status field reads *Reboot of System Complete*.
8.
Click the OnLine Tree tab in the Workspace window to view the devices on the System. The default
System value is 1.
9.
Right-click the associated System number (or anywhere within the tab itself) and select Refresh System.
This establishes a new connection to the specified System and populates the list with devices on that
system.
10.
Use Ctrl+S to save your existing NetLinx Project with the new changes.
FIG. 16
Device Addressing tab (changing the system value)
System Address
(default for initial
system is 1)
Check-Off to
verify change
This tab represents the only way to change the System Number associated to the
active on-board NI Master. The Master must have its power cycled to incorporate
the new System number, as often a simple reboot via Studio will not be enough
to incorporate this new number).
If the NetLinx device does not appear within the OnLine Tree tab, make sure that the
Integrated Controller’s on-board Master System Number (from within the Device
Addressing tab) is correctly assigned.
If there is a problem, use a system value of zero (0) on the NetLinx device.
The Master is set by default to DEVICE 0. Connected NetLinx device addresses
can only be changed through the Protected Setup page. The new address is
reflected within the OnLine Tree tab of the Workspace window only after the devices
are rebooted and the system is refreshed.
The system value on a Modero touch panel cannot be changed from the Device
Addressing dialog box and MUST be altered through the panel Protected Setup
page.