beautypg.com

AMX Signature Series NetLinx Integrated Controller NI-3101-SIG User Manual

Page 126

background image

Programming

116

NI-3101-SIG Signature Series NetLinx Integrated Controller

Master Send_Commands (Cont.)

Command

Description

G4WC
Add G4 Web Control devices
to Web control list displayed
by the Web server in a
browser.

The internal G4WC Send command (to Master 0:1:0) has been revised to add
G4 WebControl devices to Web control list displayed in the browser.
Syntax:

SEND_COMMAND ,"'G4WC "Name/Description",IP Address/URL,IP
Port,Enabled'"

Variables:

Name/Description = A string, enclosed in double quotes, that is the
description of the G4 Web Control instance. It is displayed in the browser.
IP Address/URL = A string containing the IP Address of the G4 Web Control
server, or a URL to the G4 Web Control server.
IP Port = A string containing the IP Port of the G4 Web Control Server.
Enabled = 1 or 0. If it is a 1 then the link is displayed. If it is a 0 then the link is
disabled.
The combination of Name/Description, IP Address/URL, and IP Port are used
to determine each unique listing.

Example:

SEND_COMMAND 0:1:0,"'G4WC "Bedroom",192.168.1.2,5900,1'"

Adds the BEDROOM control device using the IP Address of 192.168.1.2.

~IGNOREEXTERNAL-
CLOCKCOMMANDS
Set the Master so that it
cannot have it’s time set by
another device which
generates a ‘CLOCK’
command.

Syntax:

SEND_COMMAND ,"'~IGNOREEXTERNALCLOCKCOMMANDS'"

Example:

SEND_COMMAND 0:1:0,"'~IGNOREEXTERNALCLOCKCOMMANDS'"