Filters
Littleton, CO USA
Phone 303-794-2611
www.norgren.com
ALE-Filter
Malfunction
Possible cause
Remedy
Excessive pressure drop.
Micron rating of element to small
Use larger micron element size for application.
Filter element blocked.
1. Clean element (not
coalescing element). Note: Some residual
contamination will remain.
2. Replace with new element.
Flow requirement greater than
Use larger filter.
filter capacity.
Dirt passing through filter.
Element seals missing or
Replace seal
defective. (N.B. Seals not
2. Tighten element.
required on some units).
Damaged element.
Replace element.
Water passing through filter.
Water level in bowl above
Drain water.
baffle.
Flow capacity of filter
Maintain flow within capacity
exceeded.
of filter or change to filter
capable of handling desired flows.
Crazing of Polycarbonate bowl
Bowl has been cleaned with
Replace bowl.
or milky appearance.
incompatible fluid.
(Clean only in clean warm water and soap.)
Bowl is being used in an area
Replace bowl.
containing fumes or vapors
Eliminate source of problem or
incompatible with polycarbonate.
convert from plastic to metal bowls.
Compressor oil vapor may be
Replace bowl.
causing problem.
Eliminate source of problem or
convert from plastic to metal bowls.
Air intake to compressor may
Replace bowl.
contain fumes or vapor
Eliminate source of problem or
incompatible with polycarbonate.convert from
plastic to metal bowls.
Water beyond the filter
Inlet air has a high temperature
Fit dryer, pre-cool air or fit
and as it cools downstream,
filter immediately prior to application.
moisture condenses to water.
1.7