F64c/h oil removal (coalescing) filters, Ale-2-11 typical performance characteristics, Service kits – Norgren Filter Contents User Manual
Page 35: Technical data
F64C/H Oil Removal (Coalescing) Filters
Littleton, CO USA
Phone 303-794-2611
www.norgren.com
ALE-2-11
Typical Performance Characteristics
Inlet Pressure
Maximum Flow†
F64C
F64H
psig
(bar)
scfm
(dm
3
/s)
scfm
(dm
3
/s)
15
(1)
14
(6.4)
24
(11.2)
45
(3)
23
(11.0)
41
(19.3)
70
(5)
30
(14.3)
53
(24.9)
90
(6.3)
34
(16.0)
59
(28.0)
100
(7)
36
(16.9)
63
(29.5)
130
(9)
40
(19.1)
71
(33.5)
† Maximum flow to maintain stated oil removal performance.
Service Kits
Item
Type
Part Number
Service kit
F64C/H
4380-200
Service kit (pre-filter)
F64G
4380-200
Element F64G (pre-filter)
5 µm
4338-01
Element F64C
Coalescing
4344-01
Element F64H
Coalescing
4344-02
Replacement sight glass
Prismatic (standard)
4380-040
Pyrex
4380-041
Replacement drains
Automatic
3000-97
Manual
684-84
Service kit includes port seals, louver o-ring, bowl o-ring and drain gasket.
4.13 (105)†
1.46
(37)
2.91
(74)
F64C, Automatic Drain
9.40 (239)
††
1.46
(37)
6.45 (164)
2.32 (59)
7.05 (179)
F64C, 1/4 Turn Manual Drain
10.00 (254)
††
† 6.18" (157) for 3/4" ports.
†† Minimum clearance required to remove unit.
11.57 (294)
††
8.58 (218)
F64H, Automatic Drain
F64H, 1/4 Turn Manual Drain
12.20 (310)
††
9.21 (234)
Service
Indicator
Technical Data
Fluid: Compressed air
Maximum pressure: 250 psig (17 bar)
Operating temperature*: 0° to +150°F (-20° to +65°C)
* Air supply must be dry enough to avoid ice formation at temperatures below +35°F (+2°C).
Particle removal: 0.01 µm
Air quality: Within ISO 8573-1, Class 1 (particulates) and Class 2 (oil content).
Maximum remaining oil content: 0.01 mg/m3 at +70°F (+20°C) with an inlet
concentration of 17 mg/m3.
Maximum flow at 90 psig (6.3 bar) inlet pressure to maintain stated oil removal
performance:
1/2" ports: 74 scfm (35 dm3/s)
3/4" ports: 74 scfm (35 dm3/s)
1" ports: 127 scfm (60 dm3/s)
1/4 turn manual drain connection: 1/8" pipe thread
Automatic drain connection: 1/8" pipe thread
Automatic drain operating conditions (float operated):
Bowl pressure required to close drain: Greater than 5 psig (0.3 bar)
Bowl pressure required to open drain: Less than 3 psig (0.2 bar)
Minimum air flow required to close drain: 2 scfm (1 dm3/s)
Manual operation: Depress pin inside drain outlet to drain bowl
Nominal bowl size:
1 pint U.S. (0.5 liter)
1 quart U.S. (1 liter)
Materials:
Body: Aluminum
Yoke: Aluminum
Bowl: Aluminum
Liquid level indicator: Pyrex
Element: Synthetic fibre and polyurethane foam
Elastomers: Synthetic rubber
Service life indicator:
Body: Transparent nylon
Internal parts: Acetal
Spring: Stainless steel
Elastomers Nitrile
An automatic drain is a two-way valve, which will close when the system is
pressurized. The drain opens when the float rises due to accumulated liquid
and on depressurization.