Operation commands

Command

Syntax

Response

Lock front panel

LOCK-FP LOCK-MODE

Short form: LCK LOCK-MODE

LOCK-FP LOCK-MODE RESULT

Get front panel locking state

LOCK-FP?

LOCK-FP LOCK-MODE

Parameters Description:

LOCK-MODE = Front panel locking state:

"0" or "off" to unlock front panel buttons.
"1" or "on" to lock front panel buttons.

Restart device

RESET

RESET OK

Switch to protocol 2000*

P2000

P2000 OK

* Protocol 2000 has command to switch back to ASCII protocol (like protocol 3000)

Audio parameters commands

Command

Syntax

Response

Set audio level in specific

amplifier stage.

AUD-LVL STAGE, CHANNEL, VOLUME

Short form: ADL STAGE, CHANNEL, VOLUME

AUD-LVL STAGE,

CHANNEL, VOLUME

Read audio volume level

AUD-LVL? STAGE, CHANNEL

Short form: ADL? STAGE, CHANNEL

AUD-LVL STAGE,

CHANNEL, VOLUME

Set audio bass level

BASS OUTPUT,BASS

Short form: ADB,

OUTPUT,BASS

BASS

OUTPUT,BASS

Read audio bass level

BASS

?

OUTPUT

Short

form

:

ADB? OUTPUT

BASS

OUTPUT,BASS

Set audio treble level

TREBLE

OUTPUT,TREBLE

Short

form

:

ADT,

OUTPUT,TREBLE

TREBLE

OUTPUT,

TREBLE

Read audio treble

TREBLE

?

OUTPUT

Short

form

:

ADT? OUTPUT

TREBLE

OUTPUT

TREBLE

Parameters Description:

STAGE =

"In","Out"
or
Numeric value (present audio processing stage). For example: "0" for Input level, "1" for Pre-Amplifier, "2" for

Amplifier (Out) etc.

OUTPUT = Output #

CHANNEL = Input or Output #

VOLUME = Audio parameter in Kramer units, precede minus sign for negative values.

++

increase current value,

--

decrease current value

MUTE MODE = 1 – Mute

0 – Unmute