Kramer Protocol
48
Operation commands
Command
Syntax
Response
Lock front panel
LOCK-FP LOCK-MODE
Short form: LCK LOCK-MODE
LOCK-FP LOCK-MODE RESULT
Get front panel locking state
LOCK-FP?
LOCK-FP LOCK-MODE
Parameters Description:
LOCK-MODE = Front panel locking state:
"0" or "off" to unlock front panel buttons.
"1" or "on" to lock front panel buttons.
Restart device
RESET
RESET OK
Switch to protocol 2000*
P2000
P2000 OK
* Protocol 2000 has command to switch back to ASCII protocol (like protocol 3000)
Audio parameters commands
Command
Syntax
Response
Set audio level in specific
amplifier stage.
AUD-LVL STAGE, CHANNEL, VOLUME
Short form: ADL STAGE, CHANNEL, VOLUME
AUD-LVL STAGE,
CHANNEL, VOLUME
Read audio volume level
AUD-LVL? STAGE, CHANNEL
Short form: ADL? STAGE, CHANNEL
AUD-LVL STAGE,
CHANNEL, VOLUME
Set audio bass level
BASS OUTPUT,BASS
Short form: ADB,
OUTPUT,BASS
BASS
OUTPUT,BASS
Read audio bass level
BASS
?
OUTPUT
Short
form
:
ADB? OUTPUT
BASS
OUTPUT,BASS
Set audio treble level
TREBLE
OUTPUT,TREBLE
Short
form
:
ADT,
OUTPUT,TREBLE
TREBLE
OUTPUT,
TREBLE
Read audio treble
TREBLE
?
OUTPUT
Short
form
:
ADT? OUTPUT
TREBLE
OUTPUT
TREBLE
Parameters Description:
STAGE =
"In","Out"
or
Numeric value (present audio processing stage). For example: "0" for Input level, "1" for Pre-Amplifier, "2" for
Amplifier (Out) etc.
OUTPUT = Output #
CHANNEL = Input or Output #
VOLUME = Audio parameter in Kramer units, precede minus sign for negative values.
++
increase current value,
--
decrease current value
MUTE MODE = 1 – Mute
0 – Unmute