Connecting and Configuring the VP-16x18AK

19

19

Note:

• When using a stand-alone VP-16x18AK unit set the machine number

to 1 (factory default)

• When connecting more than one VP-16x18AK set the first machine

(connected via RS-232) to be machine number 1. The other
VP-16x18AK units must each be set to a unique machine number
between 2 and 8.

Table 4: Machine Number DIP-switch Settings

Machine Number

DIP-switch Number

1

2

3

1 (Default)

OFF

OFF

OFF

2

OFF

OFF

ON

3

OFF

ON

OFF

4

OFF

ON

ON

5

ON

OFF

OFF

6

ON

OFF

ON

7

ON

ON

OFF

8

ON

ON

ON

DIP-switch 4 sets the RS-485 termination of the VP-16x18AK. Only the
first and last physical units on the RS-485 bus should be terminated, all
others must be unterminated. Moving the DIP-switch up turns the
termination off (default), moving the switch down turns the termination on.