beautypg.com

3 the at once and confirm modes, 1 toggling between at once and confirm modes, 2 confirming a switching action – Kramer Electronics VP-16x18AK User Manual

Page 25: The at once and confirm modes, Toggling between at once and confirm modes, Confirming a switching action, Section

background image

Operating the VP-16x18AK Locally via the Front Panel Buttons

21

21

7.3 The At Once and Confirm Modes

You can choose to work in the At Once or the Confirm mode. When the
VP-16x18AK is set to the At Once mode, pressing an output-input
combination implements the action immediately. In the Confirm mode (the
TAKE button is lit), the TAKE button must be pressed to execute the
switch.

The At Once Mode

In the At Once mode, execution is immediate and actions require no user
confirmation, however, no protection is provided against changing a
switching action in error.

The Confirm Mode

In the Confirm mode:

• You can enter several actions and then confirm execution by pressing

the TAKE button to simultaneously activate multiple switches

• Every action requires user confirmation which protects against

erroneous switching

• Execution is delayed

1

7.3.1 Toggling between At Once and Confirm Modes

until the user confirms the execution

To toggle between the At Once and Confirm modes:
1. Press the TAKE button to toggle from the At Once mode

2

to the

Confirm mode

3

2. Press the TAKE button to toggle from the Confirm mode back to the

At Once mode.
The TAKE button no longer lights and actions no longer require user
confirmation.

.

The TAKE button lights and actions now require user confirmation.

7.3.2 Confirming a Switching Action

To confirm a switching action (in the Confirm mode):
1. Press an output-input combination.

The corresponding input number that is displayed in the LCD readout
flashes. The TAKE button also flashes.

2. Press the flashing TAKE button to confirm the action.

The corresponding input number that is displayed in the LCD readout
no longer flashes. The TAKE button lights.

1 If the TAKE button is not pressed within one minute, the action is aborted

2 The TAKE button does not light

3 The TAKE button lights