Default Communication Parameters
38
12
Default Communication Parameters
lists the default communication parameters as used in Kramer
Electronics products.
Table 6: Communication Parameters
EDID
EDID data is passed between Input 1 and Output 1
RS-232
Protocol 2000
Protocol 3000 (Default)
Baud Rate:
9600
Baud Rate:
115,200
Data Bits:
8
Data Bits:
8
Stop Bits:
1
Stop Bits:
1
Parity:
None
Parity:
None
Command Format:
HEX
Command Format:
ASCII
Example (Output 1 to Input 1): 0x01, 0x81, 0x81, 0x81 Example (Output 1 to Input 1): #AV 1>1
Switching Protocol
P2000 -> P3000
P3000 -> P2000
Command:
0x38, 0x80, 0x83, 0x81
Command:
#P2000
Front Panel:
Press and hold Output 1 and
Output 3 simultaneously
Front Panel:
Press and hold Output 1 and
Output 2 simultaneously
Ethernet
To reset the IP settings to the factory reset values, power cycle the device while holding in the Factory
Reset button, located on the rear panel of the unit
IP Address:
192.168.1.39
Subnet mask:
255.255.255.0
Default gateway:
192.168.1.1
TCP Port #:
5000
UDP Port #:
50000
Maximum UDP Ports:
10
Maximum TCP Ports:
4
13
Factory Default EDID
Monitor
Model name VP-16X18AK
Manufacturer KRM
Plug and Play, ID
KRM0808
Serial number 2
Manufacture date
2009, ISO week 10
EDID revision 1.3
Input signal type
Analog 0.700, 0.000 (0.7 Vp-p)
Sync input support
Separate, Composite, Sync-on-green
Display type RGB color
Screen size
360 x 290 mm (18.2 in)
Power management
Standby, Suspend, Active off/Sleep
Extension blocs
None
DDC/CI
Not supported
Color characteristics
Default color space
sRGB
Display gamma
2.0
Red chromaticity
Rx 0.611 - Ry 0.329