beautypg.com

12 default communication parameters, 13 factory default edid, Default communication parameters – Kramer Electronics VP-16x18AK User Manual

Page 42: Factory default edid, Table 6: communication parameters, Section

background image

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Default Communication Parameters

38

12

Default Communication Parameters

Table 6

lists the default communication parameters as used in Kramer

Electronics products.

Table 6: Communication Parameters

EDID

EDID data is passed between Input 1 and Output 1

RS-232

Protocol 2000

Protocol 3000 (Default)

Baud Rate:

9600

Baud Rate:

115,200

Data Bits:

8

Data Bits:

8

Stop Bits:

1

Stop Bits:

1

Parity:

None

Parity:

None

Command Format:

HEX

Command Format:

ASCII

Example (Output 1 to Input 1): 0x01, 0x81, 0x81, 0x81 Example (Output 1 to Input 1): #AV 1>1

Switching Protocol

P2000 -> P3000

P3000 -> P2000

Command:

0x38, 0x80, 0x83, 0x81

Command:

#P2000

Front Panel:

Press and hold Output 1 and

Output 3 simultaneously

Front Panel:

Press and hold Output 1 and

Output 2 simultaneously

Ethernet

To reset the IP settings to the factory reset values, power cycle the device while holding in the Factory

Reset button, located on the rear panel of the unit

IP Address:

192.168.1.39

Subnet mask:

255.255.255.0

Default gateway:

192.168.1.1

TCP Port #:

5000

UDP Port #:

50000

Maximum UDP Ports:

10

Maximum TCP Ports:

4

13

Factory Default EDID

Monitor

Model name VP-16X18AK
Manufacturer KRM
Plug and Play, ID

KRM0808

Serial number 2
Manufacture date

2009, ISO week 10


EDID revision 1.3
Input signal type

Analog 0.700, 0.000 (0.7 Vp-p)

Sync input support

Separate, Composite, Sync-on-green

Display type RGB color
Screen size

360 x 290 mm (18.2 in)

Power management

Standby, Suspend, Active off/Sleep

Extension blocs

None

DDC/CI

Not supported


Color characteristics

Default color space

sRGB

Display gamma

2.0

Red chromaticity

Rx 0.611 - Ry 0.329