Acceptable oil for lubricating bearings, Lubricate the bearings with oil, Greased-for-life bearing lubrication – Goulds Pumps 3296 EZMAG - IOM User Manual
Page 44: Pump priming
Commissioning, Startup, Operation, and Shutdown
Oil requirements based on temperature
For the majority of operating conditions, bearing temperatures run between 120°F (49°C) and 180°F
(82°C), and you can use an oil of ISO viscosity grade 68 at 100°F (38°C). If temperatures exceed 180°F
(82°C), refer to the table for temperature requirements.
Temperature
Oil requirement
Bearing temperatures exceed 180°F (82°C)
Use ISO viscosity grade 100. Bearing temperatures
are generally about 20°F (11°C) higher than bear-
ing-housing outer surface temperatures.
Pumped-fluid temperatures exceed 350°F (177°C)
Use synthetic lubrication.
Acceptable oil for lubricating bearings
Acceptable lubricants
Brand
Lubricant type
Chevron
GTS Oil 68
Exxon
Teresstic EP 68
Mobil
DTE 26 300 SSU @ 100°F (38°C)
Philips
Mangus Oil 315
Shell
Tellus Oil 68
Royal Purple
SYNFILM ISO VG 68 Synthetic Lube
Gulf
Harmony 68
Lubricate the bearings with oil
Use a high-quality turbine oil with rust and oxidation inhibitors.
1. Remove the fill plug.
2. Fill the bearing frame with oil through the filler connection, which is located on top of the
bearing frame.
Fill the bearing frame with oil until the oil level reaches the middle of the sight glass (319).
3. Replace the fill plug.
Greased-for-life bearing lubrication
The bearing manufacturer fills greased-for-life bearings with grease and seals them at the
factory. You do not need to lubricate or seal these bearings. Refer to the Maintenance chapter
for re-greasing and maintenance procedures for these bearings.
Pump priming
Potential for leaks or flooding. Make sure that you reinstall the drain plugs, check all joints for
tightness, and flange bolts for the proper torque. Failure to follow these instructions can result
in property damage and/or moderate personal injury.
Prior to filling the pump, install all plugs and blind flanges on casing and auxiliary piping. Make
sure all openings are sealed off prior to priming pump.
42