beautypg.com

Goulds Pumps 3296 EZMAG - IOM User Manual

Page 15

background image

Product Description

• Serial number

• Item numbers of the required parts

Refer to the nameplate on the pump casing for most of the information. See Parts List for item
numbers.

Nameplate types

Nameplate

Description

ATEX

If applicable, your pump unit might have an ATEX nameplate affixed to the pump, the
baseplate, or the discharge head. The nameplate provides information about the
ATEX specifications of this pump.

Nameplate on the pump casing using English units

Nameplate on the pump casing using metric units

ATEX nameplate

Nameplate field

Explanation

II

Group 2

2

Category 2

G/D

Pump can be used when gas and dust are present

T4

Temperature class

Table 2: Temperature class definitions

Code

Maximum permissible surface

Minimum permissible surface

temperature in °F (°C)

temperature in °F (°C)

T1

842 (450)

700 (372)

T2

572 (300)

530 (277)

T3

392 (200)

350 (177)

T4

275 (135)

235 (113)

T5

212 (100)

Option not available

T6

185 (85)

Option not available

Model 3296 EZMAG Installation, Operation, and Maintenance Manual

13