beautypg.com

Goulds Pumps 3296 EZMAG - IOM User Manual

Page 37

background image

Commissioning, Startup, Operation, and Shutdown

b) Lift upwards.

1. Annular groove
2. Driver half of the coupling guard
3. Driver

6. Remove the remaining nut, bolt, and washers from the pump half of the coupling guard.

It is not necessary to remove the end plate from the pump side of the bearing housing. You
can access the bearing-housing tap bolts without removing this end plate if maintenance of
internal pump parts is necessary.

7. Remove the pump half of the coupling guard:

a) Slightly spread the bottom apart.
b) Lift upwards.

1. Annular groove
2. Pump-side end plate
3. Driver
4. Pump half of the coupling guard

Model 3296 EZMAG Installation, Operation, and Maintenance Manual