Goulds Pumps 3296 EZMAG - IOM User Manual
Page 31
![background image](/manuals/461638/31/background.png)
Installation
Suction-piping checks
Check
Explanation/comment
Checked
Flush all suction piping before you This reduces the risk of pump
connect it to the pump.
operation problems.
Check that the suction piping fit-
—
tings and joints are airtight and
have no leaks.
Check that the distance between
This minimizes the risk of cavita-
the inlet flange of the pump and
tion in the suction inlet of the
the closest elbow is at least two
pump due to turbulence.
pipe diameters.
See the Example sections for il-
lustrations.
Check that elbows in general do
See the Example sections for il-
not have sharp bends.
lustrations.
Check that the suction piping is
The suction piping must never
one or two sizes larger than the
have a smaller diameter than the
suction inlet of the pump.
suction inlet of the pump.
Install an eccentric reducer be-
See the Example sections for il-
tween the pump inlet and the
lustrations.
suction piping.
Check that the eccentric reducer
See the example illustrations.
at the suction flange of the pump
has the following properties:
• Sloping side down
• Horizontal side at the top
When suction strainers or suction Suction strainers help to prevent
bells are used, check that they are clogging.
at least three times the area of the Mesh holes with a minimum diam-
suction piping.
eter of 1/16 in. (1.6 mm) are
recommended.
If more than one pump operates
This recommendation helps you
from the same liquid source,
to achieve a higher pump perfor-
check that separate suction-piping mance.
lines are used for each pump.
If necessary, make sure that the
—
suction piping includes a drain
valve and that it is correctly in-
stalled.
Liquid source below the pump
Check
Explanation/comment
Checked
Make sure that the suction piping
This helps to prevent the occur-
is free from air pockets.
rence of air and cavitation in the
pump inlet.
Check that the suction piping
—
slopes upwards from the liquid
source to the pump inlet.
If the pump is not self-priming,
Use a foot valve with a diameter
check that a device for priming the that is at least equivalent to the
pump is installed.
diameter of the suction piping.
Liquid source above the pump
Check
Explanation/comment
Checked
Check that an isolation valve is
This permits you to close the line
installed in the suction piping at a
during pump inspection and main-
distance of at least two times the
tenance.
pipe diameter from the suction
Do not use the isolation valve to
inlet.
throttle the pump. Throttling can
cause these problems:
• Loss of priming
• Excessive temperatures
• Damage to the pump
• Voiding the warranty
Make sure that the suction piping
This helps to prevent the occur-
is free from air pockets.
rence of air and cavitation in the
pump inlet.
Model 3296 EZMAG Installation, Operation, and Maintenance Manual
29