47 lau_config_getremotecontrol (0x011c), Remote control configuration, Lau_config_getremotecontrol (0x011c) – Beijer Electronics SCOM Protocol EN User Manual
Page 93
Command Reference
Elektronik-Systeme Lauer, MAEN976
93
6.47 LAU_CONFIG_GETREMOTECONTROL
(0x011C)
Remote Control Configuration
This command returns the configuration value that indicates whether the monitor is
configured to act as a remote controller. Lauer Navigation Monitors can be used as
passive devices, but can also be set up as remote controller devices to alter the back-
light level of any other monitor within the network.
Supported since Firmware Version
MT223 NAV-230G: 1.0
MT226 NAV-230G: 1.0-DSCALE2
Command Stream
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.
Maximum Lr for this Command
9
Example
Check if the monitor at address 0.7 (group 0, address 7) is configured to control oth-
er devices remotely within a network:
According to the data returned by the monitor at address 0.7 (group 0, address 7),
the monitor is capable to control other devices remotely within a network:
0
1
2
3
4
5
6
7...8
9
0x07
ADR
0x4C
0x41
0x55
0x02
ICHKH 0x01
0x1C
ICHKD
0
1
2
3
4
5
6
7
8
0x06
ADR
0x4C
0x41
0x55
0x01
ICHKH
Ret
ICHKD
Ret
Value:
0x00: Remote control capability is disabled
0x01: Remote control capability is enabled
Type:
Byte
Length:
1
Description: Indicates, whether the monitor is used also as remote controller
0
1
2
3
4
5
6
7...8
9
0x07
0x07
0x4C
0x41
0x55
0x02
0x0D
0x01
0x1C
0xE2
0
1
2
3
4
5
6
7
8
0x06
0x07
0x4C
0x41
0x55
0x01
0x0F
0x01
0xFE