6.47 LAU_CONFIG_GETREMOTECONTROL

(0x011C)

Remote Control Configuration

This command returns the configuration value that indicates whether the monitor is
configured to act as a remote controller. Lauer Navigation Monitors can be used as
passive devices, but can also be set up as remote controller devices to alter the back-
light level of any other monitor within the network.

Supported since Firmware Version
MT223 NAV-230G: 1.0

MT226 NAV-230G: 1.0-DSCALE2

Command Stream

Response Message (Acknowledge)

Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.

Maximum Lr for this Command
9

Example
Check if the monitor at address 0.7 (group 0, address 7) is configured to control oth-
er devices remotely within a network:

According to the data returned by the monitor at address 0.7 (group 0, address 7),
the monitor is capable to control other devices remotely within a network:

0

1

2

3

4

5

6

7...8

9

0x07

ADR

0x4C

0x41

0x55

0x02

ICHKH 0x01

0x1C

ICHKD

0

1

2

3

4

5

6

7

8

0x06

ADR

0x4C

0x41

0x55

0x01

ICHKH

Ret

ICHKD

Ret

Value:

0x00: Remote control capability is disabled
0x01: Remote control capability is enabled

Type:

Byte

Length:

1

Description: Indicates, whether the monitor is used also as remote controller

0

1

2

3

4

5

6

7...8

9

0x07

0x07

0x4C

0x41

0x55

0x02

0x0D

0x01