18 etc, Elapsed time counter – Beijer Electronics SCOM Protocol EN User Manual
Page 60
Command Reference
60
Elektronik-Systeme Lauer, MAEN976
6.18 ETC
Elapsed Time Counter
Queries the total operation time in hours. Internally, each monitor is equipped with
a software counter, which counts the full number of operation hours. The counter
value is limited to 298261, which is equivalent to approximately 34 years of opera-
tion time. After this time, each monitor returns always the maximum value. The
counter is incremented only, if the monitor was powered on one full hour without
interruption. If the monitor is powered off prior one full hour, the counter will re-
main at its last value.
Supported since Firmware Version
MT223 NAV-230G: 1.2-C118
MT226 NAV-230G: 1.0-DSCALE2
Command Stream
(This command has no data)
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
(No data is returned, in case of a negative acknowledge)
Maximum Lr for this Command
11
0
1
2
3
4
5
6
0x07
ADR
0x45
0x54
0x43
0x00
ICHKH
0
1
2
3
4
5
6
7...9
10
0x06
ADR
0x45
0x54
0x43
0x03
ICHKH Hours
ICHKD
Hours
Value:
0 … 298261
Type:
Byte Array
Length:
3
Description: Number of hours. The most significant byte is transmitted first
0
1
2
3
4
5
6
0x15
ADR
0x45
0x54
0x43
0x00
ICHKH