38 lau_config_getpotmode (0x0113), Pot mode, Lau_config_getpotmode (0x0113) – Beijer Electronics SCOM Protocol EN User Manual
Page 83
Command Reference
Elektronik-Systeme Lauer, MAEN976
83
6.38 LAU_CONFIG_GETPOTMODE (0x0113)
POT Mode
Returns the local backlight level control configuration. If the local backlight control
is enabled, the backlight level can be changed using the front panel buttons and by
remote control (serial or Ethernet interface, analog or digital input). If the local back-
light control is disabled, the backlight level cannot be changed using the front panel
buttons. It can be still changed by any remote control option. The configured back-
light level control can be temporarily overridden by the SCOM command “POT”.
Supported since Firmware Version
MT223 NAV-230G: 1.0
MT226 NAV-230G: 1.0-DSCALE2
Command Stream
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.
Maximum Lr for this Command
9
Example
Get the local backlight level control configuration of the monitor at address 0.7
(group 0, address 7):
According to the data returned by the monitor at address 10.7 (group 0, address 7),
the local backlight level control is enabled:
0
1
2
3
4
5
6
7...8
9
0x07
ADR
0x4C
0x41
0x55
0x02
ICHKH 0x01
0x13
ICHKD
0
1
2
3
4
5
6
7
8
0x06
ADR
0x4C
0x41
0x55
0x01
ICHKH
Ret
ICHKD
Ret
Value:
0x00: Local backlight level control enabled
0x01: Local backlight level control disabled
Type:
Byte
Length:
1
Description: Local backlight level control mode
0
1
2
3
4
5
6
7...8
9
0x07
0x07
0x4C
0x41
0x55
0x02
0x0D
0x01
0x13
0xEB
0
1
2
3
4
5
6
7
8
0x06
0x07
0x4C
0x41
0x55
0x01
0x0F
0x00
0xFF