Beijer Electronics SCOM Protocol EN User Manual
Page 38
Command Reference
38
Elektronik-Systeme Lauer, MAEN976
Response Message (Acknowledge)
Maximum Lr for this Command
13
Example 1
Set the main signal source of monitor MT226 at address 0.15 (group 0, address 15)
to “DVI” (which is ASCII “19” with ASCII-codes 0x31 0x39):
Monitor MT226 at address 0.15 (group 0, address 15) has acknowledged the new
main signal source “DVI” (0x31 0x39):
Example 2
Decrement the main signal source of monitor MT226 at address 0.15 (group 0,
address 15):
Monitor MT226 at address 0.15 (group 0, address 15) has returned the new main
signal source “VGA” (which is ASCII “17” with ASCII-codes 0x31 0x37):
0
1
2
3
4
5
6
7...7+[LEN]-1
7+[LEN]
0x06
ADR
0x4D
0x43
0x43
LEN
ICHKH 0x98
Param Ret
ICHKD
Ret
Value:
“02”: VIDEO1
“03”: VIDEO2
“05”: SVIDEO1
“08”: CMPT1
“18”: SD-RGB
“0A”: COMP3
“17”: VGA
“19”: DVI
“1B”: HD-SDI
Type:
Two-digit ASCII-encoded hexadecimal number
Length:
2
Description: Current video signal source
0
1
2
3
4
5
6
7...9
10
0x07
0x0F
0x4D
0x43
0x43
0x03
0x13
0x98
0x31
0x39
0xFD
0
1
2
3
4
5
6
7...11
12
0x06 0x0F 0x4D 0x43 0x43 0x05 0x1A 0x98 0x31 0x39 0x31 0x39 0x93
0
1
2
3
4
5
6
7...8
9
0x07
0x0F
0x4D
0x43
0x43
0x02
0x14
0x98
0x2D
0x3A
0
1
2
3
4
5
6
7...10
11
0x06
0x0F
0x4D 0x43
0x43
0x04
0x13
0x98
0x2D 0x31
0x37
0xD2