Interface Configuration
Elektronik-Systeme Lauer, MAEN976
9
1
Interface Configuration
A command can be sent either using the serial interface (RS232 or RS485) or the
Ethernet interface via UDP.
This is the default configuration for the two interfaces:
Although the Lauer Navigation Monitors support serial port data transfer speed at
different rates and configurable UDP ports for the Ethernet communication, the giv-
en default configuration should be used for compatibility issues.
Interface type
Default configuration
Serial (RS232 or RS485)
9600 bits/second, 8 data bits, 1 start bit, 1 stop bit
Ethernet
UDP receive port 10000, UDP send port 10001