58 lau_control_buzzer (0x0202), Buzzer control, Lau_control_buzzer (0x0202) – Beijer Electronics SCOM Protocol EN User Manual
Page 109
Command Reference
Elektronik-Systeme Lauer, MAEN976
109
6.58 LAU_CONTROL_BUZZER (0x0202)
Buzzer Control
Activates the built-in buzzer, if available.
Supported since Firmware Version
MT223 NAV-230G: 1.0
MT226 NAV-230G: 1.0-DSCALE2
Command Stream
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
Under normal operation conditions, a negative acknowledge message does not con-
tain any status data in response to this command. This response message is only sent,
if there is insufficient data in the command stream.
Maximum Lr for this Command
11
0
1
2
3
4
5
6
7...9
10
0x07
ADR
0x4C
0x41
0x55
0x03
ICHKH 0x02 0x02 Param
ICHKD
Param
Value:
0x00: Disable buzzer
0x01: Enable buzzer
Type:
Byte
Length:
1
Description: Buzzer control
0
1
2
3
4
5
6
7...9
10
0x06
ADR
0x4C
0x41
0x55
0x03
ICHKH 0x02 0x02 Ret
ICHKD
Ret
Value:
0x00: Buzzer disabled
0x01: Buzzer enabled
Type:
Byte
Length:
1
Description: Current buzzer state
0
1
2
3
4
5
6
7...8
9
0x15
ADR
0x4C
0x41
0x55
0x02
ICHKH
0x02
0x02
ICHKD