Beijer Electronics SCOM Protocol EN User Manual
Page 102
Command Reference
102
Elektronik-Systeme Lauer, MAEN976
Example
Read the lower backlight level range limit configuration for the monitor at address
0.7 (group 0, address 7):
According to the data returned by the monitor at address 0.7 (group 0, address 7),
the lower backlight level range limit is 0 (0x00). This means, the user cannot adjust
the backlight level lower than the ECDIS backlight level, using the front panel key:
0
1
2
3
4
5
6
7...8
9
0x07
0x07
0x4C
0x41
0x55
0x02
0x0D
0x01
0x22
0xDC
0
1
2
3
4
5
6
7
8
0x06
0x07
0x4C
0x41
0x55
0x01
0x0F
0x00
0xFF