beautypg.com

Beijer Electronics SCOM Protocol EN User Manual

Page 43

background image

Command Reference

Elektronik-Systeme Lauer, MAEN976

43

Maximum Lr for this Command
13

Example 1
Set the PIP window size of monitor MT226 at address 0.15 (group 0, address 15) to
“Small” (which is ASCII “02” with ASCII codes 0x30 0x32):

Monitor MT226 at address 0.15 (group 0, address 15) has acknowledged the new
PIP window size “Small” (0x30 0x32):

Example 2
Reset the PIP window size of monitor MT226 at address 0.15 (group 0, address 15):

Monitor MT226 at address 0.15 (group 0, address 15) has returned the default PIP
mode “PIP off ” (which is ASCII “00” with ASCII-codes 0x30 0x30):

Example 3
Query the current PIP window size of monitor MT226 at address 0.15 (group 0, ad-
dress 15):

Monitor MT226 at address 0.15 (group 0, address 15) has returned the value “PIP
off ” indicating that the PIP window is not visible (which is ASCII “00” with ASCII-
codes 0x30 0x30):

0

1

2

3

4

5

6

7...9

10

0x07

0x0F

0x4D

0x43

0x43

0x03

0x13

0xA6

0x30

0x32

0xF7

0

1

2

3

4

5

6

7...11

12

0x06 0x0F 0x4D 0x43 0x43 0x05 0x12 0xA6 0x30 0x32 0x30 0x32 0x95

0

1

2

3

4

5

6

7...8

9

0x07

0x0F

0x4D

0x43

0x43

0x02

0x14

0xA6

0x52

0x07

0

1

2

3

4

5

6

7...10

11

0x06

0x0F

0x4D 0x43

0x43

0x04

0x13

0xA6 0x52

0x30

0x30

0xA7

0

1

2

3

4

5

6

7...8

9

0x07

0x0F

0x4D

0x43

0x43

0x02

0x14

0x98

0x3F

0x1A

0

1

2

3

4

5

6

7...10

11

0x06

0x0F

0x4D 0x43

0x43

0x04

0x13

0xA6 0x3F

0x30

0x30

0xBA