8 mcc_scalingmode (0x8c), Scaling mode, Mcc_scalingmode (0x8c) – Beijer Electronics SCOM Protocol EN User Manual
Page 34
Command Reference
34
Elektronik-Systeme Lauer, MAEN976
6.8 MCC_SCALINGMODE (0x8C)
Scaling Mode
Sets or queries the main scaling mode.
Supported since Firmware Version
MT223 NAV-230G: 1.0
MT226 NAV-230G: 1.0-DSCALE2
Command Stream
0
1
2
3
4
5
6
7...7+[LEN]-1
7+[LEN]
0x07
ADR
0x4D
0x43
0x43
LEN
ICHKH 0x8C
Param
ICHKD
MT223 NAV-230G
Param: QUERY
Value:
“?” (0x3F)
Type:
ASCII character
Length:
1
Description: Query the current scaling mode
MT226 NAV-230G
Param: ABSOLUTE
Value:
“0”: Full screen
“1”: Letterbox
“2”: Pillarbox
“3”: Pillarbox expand
“4”: Letterbox expand
“5”: Waterglass
“6”: Panoramic
Type:
One-digit ASCII-encoded hexadecimal number
Length:
1
Description: New scaling mode
Param: RESET
Value:
“R” or “r” (0x52 or 0x72)
Type:
ASCII character
Length:
1
Description: Reset the scaling mode to an internally predefined value
Param: QUERY
Value:
“?” (0x3F)
Type:
ASCII character
Length:
1
Description: Query the current scaling mode