Beijer Electronics SCOM Protocol EN User Manual
Page 118
Command Reference
118
Elektronik-Systeme Lauer, MAEN976
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.
Maximum Lr for this Command
11
Example
Assign command “Special functions 2” to the digital input port of the monitor at ad-
dress 0.7 (group 0, address 7):
The monitor at address 0.7 (group 0, address 7) acknowledged the new command
for the digital input port:
0
1
2
3
4
5
6
7...9
10
0x06
ADR
0x4C
0x41
0x55
0x03
ICHKH 0x02
0x06
Ret
ICHKD
Ret
Value:
0x00: Command “No operation”
0x01: Command “Set brightness”
0x02: Command “Special functions 1”
0x03: Command “Special functions 2”
Type:
Byte
Length:
1
Description: Current command assigned to the digital I/O port
0
1
2
3
4
5
6
7...9
10
0x07
0x07
0x4C
0x41
0x55
0x03
0x0C
0x02
0x06
0x02
0xF5
0
1
2
3
4
5
6
7...9
10
0x06
0x07
0x4C
0x41
0x55
0x03
0x0D
0x02
0x06
0x02
0xF5