4 pot, Local control – Beijer Electronics SCOM Protocol EN User Manual
Page 24
Command Reference
24
Elektronik-Systeme Lauer, MAEN976
6.4 POT
Local Control
Enables or disables the local backlight level control. If the local backlight control is
enabled, the backlight level can be changed using the front panel buttons and by re-
mote control (serial or Ethernet interface, analog or digital input). If the local back-
light control is disabled, the backlight level cannot be changed using the front panel
buttons. It can be still changed by any remote control option.
Supported since Firmware Version
MT223 NAV-230G: 1.0
MT226 NAV-230G: 1.0-DSCALE2
Command Stream
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
0
1
2
3
4
5
6
7
8
0x07
ADR
0x50
0x4F
0x54
0x01
ICHKH Local control
ICHKD
Local control
Value:
0x00: Disable local control
0xFF: Enable local control
Type:
Byte
Length:
1
Description: New local control configuration
0
1
2
3
4
5
6
7
8
0x06
ADR
0x50
0x4F
0x54
0x01
ICHKH Local control
ICHKD
Local control
Value:
0x00: Local control disabled 0xFF: Local control enabled
Type:
Byte
Length:
1
Description: Current local control configuration
0
1
2
3
4
5
6
7
8
0x15
ADR
0x50
0x4F
0x54
0x01
ICHKH Local control
ICHKD
Local control
Value:
0x00: Local control disabled 0xFF: Local control enabled
Type:
Byte
Length:
1
Description: Last local control configuration