7 mcc_contrast (0x82), Contrast, Mcc_contrast (0x82) – Beijer Electronics SCOM Protocol EN User Manual
Page 31
Command Reference
Elektronik-Systeme Lauer, MAEN976
31
6.7 MCC_CONTRAST (0x82)
Contrast
Adjusts or queries the contrast value of the video controller.
Supported since Firmware Version
MT223 NAV-230G: 1.0
MT226 NAV-230G: 1.0-DSCALE2
Command Stream
0
1
2
3
4
5
6
7...7+[LEN]-1
7+[LEN]
0x07
ADR
0x4D
0x43
0x43
LEN
ICHKH 0x82 Ext
Ret
ICHKD
Ext:
Value:
“A” or “a” (0x41 or 0x61)
Type:
ASCII character
Length:
1
Description: Command extension.
This character must be always sent as part of the sub-
command.
Param: ABSOLUTE
Value:
“00”: low … “FF”: high
Type:
Two-digit ASCII-encoded hexadecimal number
Length:
2
Description: New contrast value
Param: INC
Value:
“+” (0x2B)
Type:
ASCII character
Length:
1
Description: Increment the current contrast value
Param: DEC
Value:
“-” (0x2D)
Type:
ASCII character
Length:
1
Description: Decrement the current contrast value
Param: RESET
Value:
“R” or “r” (0x52 or 0x72)
Type:
ASCII character
Length:
1
Description: Reset the contrast to an internally predefined value
Param: QUERY
Value:
“?” (0x3F)
Type:
ASCII character
Length:
1
Description: Query the current contrast value