Using the VISCA RS-422 Connector
Plug

1

Insert a wire (AWG Nos. 28 to 18) into the desired
wire opening on the VISCA RS-422 connector
plug, and tighten the screw for that wire using a flat-
head screwdriver.

2

Insert the VISCA RS-422 connector plug into the
VISCA RS-422 connector.

To remove the connector plug

Grasp both ends of the VISCA RS-422 connector plug
and pull it out as shown in the illustration.

Notes

• In order to stabilize the voltage level of the signal,

connect both ends to GND.

• When the connections using the VISCA RS-422

connectors are made, the VISCA RS-232C connection
is not available.

• The maximum connection distance with the VISCA

RS-422 connection is approximately 1,200 m (3,937
feet).