beautypg.com

Frost protection faults – Karcher B 60 W Bp Pack User Manual

Page 37

background image

– 15

Set the key switch at the operator con-
sole to "0" and remove the key.

Loosen the tank lock and tilt the tank
upwards.

Clamp off the minus pole of the battery.

Clamp off the remaining cables from the
battery.

Unscrew the fastening angle.

Remove the batteries.

Dispose of the used batteries according
to the local provisions.

To ensure a reliable operation of the appli-
ance maintenance contracts can be con-
cluded with the competent Kärcher sales
office.

In case of danger of frost:

Empty the fresh and dirt water reser-
voirs.

Store the appliance in a frost-protected
room.

ƽ

Danger

Risk of injury! Before carrying out any tasks
on the machine, set the main key to "0" and
remove key and plug of the charger.

Drain and dispose of the dirt water and
the residual fresh water.

In case of faults that cannot be remedied
using the table below please contact the
customer service.

Removing the batteries

Maintenance contract

Frost protection

Faults

Fault

Remedy

Appliance cannot be
started

Stand-by, turn key switch to "0", then set it back to "1".
Check fuse F2*, replace if required. *
Check battery; charge it if required.

Machine does not
move

Check whether the immobilizing brake (optional) has been ap-
plied.

Insufficient water
quantity

Check fresh water level, refill tank if necessary.
Check hoses for blockages; clean if required.

Insufficient vacuum
performance

Clean the seals between dirt water reservoir and cover and
check for tightness, replace if required.
Clean the fluff filter.
Clean the vacuum lips on the vacuum bar, replace if required
Check suction hose for blockages; clean if required.
Check the suction hose for tightness; replace if required.
Check if the cover on the dirt water discharge hose is closed
Check the setting of the vacuum bar.

Insufficient cleaning
result

Set/ adjust contact pressure.
Check the brushes for wear, replace if required.

Brushes do not turn

Reduce contact pressure.
Check if foreign matters block the brushes; remove foreign mat-
ter if required.
If over-current switch in the electronics system has been trig-
gered, turn key switch to "0", then set it back to "1".

* Remove screws of the electronics system and tilt the electronics cover with charger
downwards

37

EN

This manual is related to the following products: