Disabling all Diagnostic Options For a Device
There are two ways to disable all diagnostics for a device:
In the Edit Options window, select Delete to remove the device from the Diagnostics Options
page and disable all diagnostics.
In the Edit Options window, deselect all selected diagnostics options and click Update. This
disables all diagnostics for this device, but leaves the device on the Diagnostics Options page.
Creating and Recalling Diagnostics Presets
The Store and Recall options in the Edit Options window allow you to save and recall preset diagnostics
configurations.
1.
Click the Presets down arrow to open a list of previously stored Presets. By default, the only preset
is called 0: All Devices, All Notifications. This default Preset cannot be modified.
2.
Select an empty Preset (for example 1:)
3.
Select the desired diagnostic options, and click Store.
4.
A popup window prompts you to name this Preset. Enter a name and click OK.
To recall an existing Preset, select it from the drop-down list and click on Recall.
Diagnostic Options (Cont.)
Diagnostic option
Description
Channel Changes
• Input
Generates a message when there is an input channel change (i.e. Push/Release) in
the target device.
• Output
Generates a message when there is an output channel change (i.e. CHON/CHOFF)
in the target device.
• Feedback
Generates a message when there is a feedback channel change in the target
device.
Device Options
• Level Changes From
Generates a message when there is a level channel change from the target device.
• Level Changes To
Generates a message when there is a level channel change to the target device.
• Strings To
Generates a message when there is a string sent to the target device.
• Strings From
Generates a message when there is a string from the target device.
• Commands To
Generates a message when there is a command to the target device.
• Commands From
Generates a message when there is a command from the target device.
• Custom Events From
Generates a message there is a custom event occurring from the target device.
Presets are saved via cookies, so they do not persist across multiple browsers/
computers.
A Preset MUST be Recalled before clicking the Update button. If you do not press
this button, none of the fields or checkboxes are modified or selected. In essence, all
options become disabled.