Chapter 8: Operations, Administration, and Maintenance (OAM)

100

Remote Stable
Indicates remote OAM Client acknowledgment of and satisfaction with
local OAM state information. Possible values are:

ˆ

Yes – Indicates that the selected port has seen and is satisfied with
local state information.

ˆ

No – Indicates that the selected port either has not seen or is not
satisfied with local state information. (default)

Critical Event
Indicates a severe error condition that does not result in a complete
reset or reboot by the peer entity.

ˆ

Yes – A severe error condition has occurred.

ˆ

No – No severe error condition has occurred. (default)

Dying Gasp
Indicates an unrecoverable failure condition has occurred when an
equipment is about to be reset, reboot, or otherwise having a power
failure.

ˆ

Yes – An unrecoverable local failure condition has occurred.

ˆ

No – No unrecoverable local failure condition has occurred.
(default)

Link Fault
Indicates the PHY has determined a fault has occurred in the receive
direction of the local port.

ˆ

Yes – A link fault has occurred.

ˆ

No – No link fault has occurred. (default)

OAM Version
Indicates the version supported by the DTE. This field contains the
value “0x01” to claim compliance with Version 1 of this protocol.

Config Revision
Indicates the current revision of the Information TLV. The value of this
field starts at zero and be incremented each time something in the
Information TLV changes. Upon reception of an Information TLV from
a peer, an OAM Client may use this field to decide if it needs to be
processed (an Information TLV that is identical to the previous
Information TLV doesn't need to be parsed as nothing in it has
changed).

Vendor Information
Indicates the 32-bit identifier that may be used to differentiate a
vendor’s product models/versions.

Vendor OUI
Indicates the vendor’s 24-bit Organizationally Unique Identifier (OUI).