beautypg.com

A100 null modem adapter, 1. null modem connections, Voltage (volts) current (amps) power (watts) – Campbell Scientific PS200/CH200 12 V Charging Regulators User Manual

Page 59

background image

PS200/CH200 12 V Charging Regulators

0

1

2

3

4

5

6

7

8

9 10 11 12 13 14 15 16 17 18 19 20 21

0

0.9

1.8

2.7

3.6

4.5

0

10

20

30

40

50

60

70

Voltage (Volts)

Current (Amps)

Power (Watts)

4.5

0

I

m

70

0

P

m

21

0

Vc

m

FIGURE 7-2. 70 W solar panel I – V and power characteristics

8. A100 Null Modem Adapter

The A100 adapter has two 9-pin CS I/O ports with a null modem between
them. The ports are used to connect two 9-pin devices (e.g., modems or RF
radios) that would normally be connected to the CS I/O port of a Campbell
datalogger. The charger supplies 12 volts and 5 volts to the appropriate pins on
the connector for powering the connected devices. This functionality is
required in a station where a datalogger will not be present, such as a phone-to-
RF base station. The A100 cannot be used as a null modem between two RS-
232 devices.

FIGURE 8-1. Null modem connections