Appendix g. crbasic program library, G.1 dynamic measurements, G.1.1 – Campbell Scientific CDM-VW300 Series Dynamic Vibrating-Wire Analyzer System User Manual
Page 93: 20 hz measurement example — one cdm-vw300, two, Vw300, two channels, S are available in appendix g

Appendix G. CRBasic Program Library
The following example programs are compatible with CR3000, CR1000, and 
CR800 dataloggers without modification. The programs are available for 
download at
ook for "CDM-VW300
Example Programs." The programs are named with a .CR3 extension and can 
be renamed as .CR1 or .CR8 without modification to run on the CR1000 or 
CR800 dataloggers. To use programs from this library, 
1. Select the desired program and save it to your PC.
2. Open CRBasic Editor.
3. Open the program file just downloaded to edit, if necessary.
4. Send the program to the datalogger using the program Send command
in RTDAQ or LoggerNet.
5. Monitor the operation of the system with the numeric and graphical
monitors available with RTDAQ or LoggerNet.
G.1 Dynamic Measurements
G.1.1 20 Hz Measurement Example — One CDM-VW300, Two
Channels
'===20Hz-1Device2Ch_4-25-13.CR3===
'CR3000 datalogger
'CDM-VW300 vibrating-wire analyzer
'Program to read 20 Hz dynamic data from one CDM-VW300 analyzer measuring two channels
'IMPORTANT -- Ensure that the CPI address coded on the following line matches the address
'reported for the attached analyzer in the DevConfig or DVWTool software.
Const
CPI_ADDR
=
1
'<<<<<<<<<<<<<   Public  Freq(2)  'dynamic frequencies  Public  Diag(2)  As Long   'diagnostic code    Public  StaticFreq(2)  'Static (1 Hz output) frequencies  Public  Therm(2)  'Thermistor readings  'Standard Deviation of the dynamic readings that occurred during the latest one-second interval  Public  DynStdDev(2)    'The following arrays are used to configure the CDM-VW300. Refer to the CDM_VW300Config  'instruction used below  ' CH1 CH2  ' --- ---  'Set to true (Enabled=1, Disabled=0) only those channels which have sensors connected  Dim  Enable(2)  As Long   =  { 1, 1}  'Specify the target/desired resonant amplitude at which the sensor will be maintained  'via excitation, given in volts. This should be in the range 0.010 to 0.001  Dim  Max_AMP(2)  =  { 0.002, 0.002}  'Low Frequency Boundary (sensor frequency should never fall below  'this value regardless of environmental changes)  Dim  F_Low(2)  =  { 300, 300}  'High Frequency Boundary (sensor frequency should never exceed  'this value regardless of environmental changes)  Dim  F_High(2)  =  { 6000, 6000}  'Output Format - Hz vs. Hz^2 :: Value of 0 – measured frequency is given in units of Hz,  'Value of 1 – measured frequency is squared and given in units of Hz^2  Dim  OutForm(2)  As Long   =  { 0, 0}  'Multiplier (factor) to be applied to sensor output frequency  Dim  Mult(2)  =  { 1.0, 1.0}  G-1 