beautypg.com

1 device name, 2 cpi bus speed, Device name – Campbell Scientific CDM-VW300 Series Dynamic Vibrating-Wire Analyzer System User Manual

Page 44: Cpi bus speed

background image

CDM-VW300 Series Dynamic Vibrating-Wire Analyzers

Setting Description

DVWTool PC Software

Setting Name

DevConfig PC Software

Setting Name

CRBasic Datalogger

Instructions /

Parameters

Multiplier

Multiplier

Multiplier

CDM_VW300Config()

Mult

Offset

Offset

Offset

CDM_VW300Config()

Offset

Steinhart-Hart
coefficients

Steinhart-Hart
Thermistor Coeff
A

Thermistor A

CDM_VW300Config()

SteinA

Steinhart-Hart
Thermistor Coeff
B

Thermistor B

CDM_VW300Config()

SteinB

Steinhart-Hart
Thermistor Coeff
C

Thermistor C

CDM_VW300Config()

SteinC

Rainflow-histogram
output configuration

Rainflow | Number of
Mean Bins

Rainflow Mean Bins

CDM_VW300Config()

RF_MeanBins

Rainflow | Number of
Amp Bins

Rainflow Amp Bins

CDM_VW300Config()

RF_AmpBins

Rainflow | Low Limit

Rainflow Low Limit

CDM_VW300Config()

RF_LowLim

Rainflow | High Limit

Rainflow High limit

CDM_VW300Config()

RF_HighLim

Rainflow | Minimum
Change

Rainflow Min Change

CDM_VW300Config()

RF_Hyst

Rainflow | Rainflow Form

Rainflow Form

CDM_VW300Config()

RF_Form

7.5.1 Device Name

This setting specifies an alphanumeric name for the analyzer. This is an
optional setting and is not available in the CRBasic datalogger instruction
setup.

7.5.2 CPI Bus Speed

This setting specifies the speed at which the CDM-VW300 communicates with
the CPI bus. Speed options are 50, 125, 250, 500, and 1000 kbps. In a
CRBasic program, use the CPISpeed() instruction to set this setting. Shorter
CPI cable lengths allow for a faster CPI bus speed.

34