beautypg.com

Flytec 6030-gps, 3the setting menus, 1 user settings – Flytec 6030 * User Manual

Page 36

background image

Flytec 6030-GPS

36 / 62

charging has been completed. If one keeps the charger connected to power supply for a
couple of hours after extinction of the LED, then the energy stored in the accumulator shall
be increased by a few more percent by trickle mode.

Caution:

during charging the outside temperature should be between + 5 °C and + 35 °C.

It is possible to check during charging the accumulator’s voltage, however, the FLYTEC 6030
GPS
should be switched-off during charging.


3

The Setting Menus


Prolonged pressing of the OK/Menu key gives access to the setting mode. With the ▼ key
one of the menu items is selected and pressing the OK key gives access to the relevant
subdirectory.


3.1 User Settings


A series of settings allow the instrument to be programmed in accordance to the user’s
wishes. Every pilot may realise his very own ideas here. All the basic settings may be
set comfortably on the PC by use of the PC-Software „Flychart“ and be transferred later
to the instrument via the PC interface. Manufacturer’s approved basic settings are called-up
with

Basic Settings / Init

EEPROM.

Please note to use this setting only in case of emergency,

because hereby all WPs and Routes shall be erased. In most cases the possible setting
range and its value valid previously is indicated individually for each of the settings. If this
value should be modified, pressing of the OK key gives access to change mode, the
value to be modified will blink and can now be changed by use of the ▼ and ▲ keys.
Pressing the OK key confirms the new value, pressing of the ESC key recalls the previous
setting.


Term Denotation

More

Factory

setting

Variometer

info

Ground filter

Diagnose of time constant f. Vario a.
Speed

1.1

12 (

≈ 1,2 sec)

Digital Vario
Integrator

Shift Integr.- Netto-Vario; Integr.-time
constant

1.3

Integr. 1 30 sec
1 sec

Threshold last climb

Threshold for the last climb

Day specific climb

Time constant for the time-average of
specific climb during this day

1.11

0,5 ...10 min
10 min

Variometer
Acoustic

Acoustics settings

Climb tone frequency, modulation; sink
tone freq., Acoustic dampening;
Pitch

1.7

1200 Hz; Mod = 5,
700 Hz, 8, Pi = 3

Climb acoustic,
activation threshold

Fine tuning of climbing tone,
max. 20 cm

2

cm/sec

Sink tone act.
threshold

Activation point of Sink tone

1.7

0,8 m/s (ft/m)

Speed

Speed mode

True or Indicated Airspeed

5.3

0 = true airsp.