beautypg.com

Eneral, Ontroller, Pecifications – Red Lion PAX2C User Manual

Page 3

background image

3

g

eneral

C

OnTrOller

s

peCifiCaTiOns

1. DISPLAY: Negative image LCD with tri-color backlight.

The display is divided into seven independently programmable color zones:

Line 1, Line 2, Universal Annunciators (1-4) & Mnemonics

Line 1 and 2: 4 digits each line

Display Range: -1999 to 9999

Units - Programmable 3 digit units annunciator

Bar Graph - Programmable 8 segment bar graph

Universal Annunciator 1 thru 4: Programmable 2 digit annunciator

Status Mnemonics: MAN - Controller is in Manual Mode

REM – Controller is in Remote Mode

Vertical Model Digit Size: Line 1 - 0.51" (13 mm), Line 2 - 0.44" (11.2 mm)

Horizontal Model Digit Size: Line 1 - 0.62" (15.7 mm), Line 2 - 0.47" (12.0 mm)

2. POWER:

AC Power: 40 to 250 VAC, 50/60 Hz, 20 VA

DC Power: 21.6 to 250 VDC, 8 W

Isolation: 2300 Vrms for 1 min. to all inputs and outputs.

3. KEYPAD: 2 programmable function keys, 4 keys total

4. A/D CONVERTER: 24 bit resolution

5. DISPLAY MESSAGES:

“OLOL” - Appears when measurement exceeds + signal range.

“ULUL” - Appears when measurement exceeds - signal range

“Shrt” - Appears when shorted sensor is detected. (RTD range only)

“OPEN” - Appears when open sensor is detected. (TC/RTD range only)

“. . . . ” - Appears when display values exceed + display range.

“- . . . ” - Appears when display values exceed - display range.

6. INPUT CAPABILITIES:

Current Input:

INPUT RANGE

ACCURACY *

(18 to 28°C)

ACCURACY *

(0 to 50°C)

IMPEDANCE

RESOLUTION

± 250 µADC

0.03% of rdg

+ 0.03µA

0.12% of rdg

+ 0.04µA

1.11 K

W

0.1µA

± 2.5 mADC

0.03% of rdg

+ 0.3µA

0.12% of rdg

+ 0.4µA

111

W

1µA

± 25 mADC

0.03% of rdg

+ 3µA

0.12% of rdg

+ 4µA

11.1

W

10µA

± 250 mADC 0.05% of rdg

+ 30µA

0.12% of rdg

+ 40µA

1.1

W

0.1mA

± 2 ADC

0.5% of rdg

+ 0.3mA

0.7% of rdg

+ 0.4mA

0.1

W

1mA

Voltage Input:

INPUT RANGE

ACCURACY *

(18 to 28°C)

ACCURACY *

(0 to 50°C)

IMPEDANCE

RESOLUTION

± 250 mVDC

0.03% of rdg

+ 30µV

0.12% of rdg

+ 40µV

451 K

W

0.1mV

± 2.0 VDC

0.03% of rdg

+ 0.3mV

0.12% of rdg

+ 0.4mV

451 K

W

1mV

± 10 VDC

0.03% of rdg

+ 3mV

0.12% of rdg

+ 4mV

451 K

W

1mV

± 25 VDC

0.03% of rdg

+ 3mV

0.12% of rdg

+ 4mV

451 K

W

10mV

± 100 VDC

0.3% of rdg

+ 30mV

0.12% of rdg

+ 40mV

451 K

W

0.1V

± 200 VDC

0.3% of rdg

+ 30mV

0.12% of rdg

+ 40mV

451 K

W

0.1V

Temperature Inputs:

Scale: °F or °C

Offset Range: -1999 to 9999 display units.

Thermocouple Inputs:

Input Impedance: 20MW

Lead Resisitance Effect: 0.03 µV/W

Max Continuous Overvoltage: 30 VDC

INPUT

TYPE

RANGE

ACCURACY*

(18 to 28 °C)

ACCURACY*

(0 to 50 °C) STANDARD

WIRE COLOR

ANSI

BS 1843

T

-200 to 400°C

1.2°C

2.1°C

ITS-90

(+) blue

(-) red

(+) white

(-) blue

E

-200 to 750°C

1.0°C

2.4°C

ITS-90

(+) purple

(-) red

(+) brown

(-) blue

J

-200 to 760°C

1.1°C

2.3°C

ITS-90

(+) white

(-) red

(+) yellow

(-) blue

K

-200 to 1250°C

1.3°C

3.4°C

ITS-90

(+) yellow

(-) red

(+) brown

(-) blue

R

0 to 1768°C

1.9°C

4.0°C

ITS-90

no

standard

(+) white

(-) blue

S

0 to 1768°C

1.9°C

4.0°C

ITS-90

no

standard

(+) white

(-) blue

B

150 to 300°C

300 to 1820°C

3.9°C

2.8°C

5.7°C

4.4°C

ITS-90

no

standard

no

standard

N

-200 to 1300°C

1.3°C

3.1°C

ITS-90

(+) orange

(-) red

(+) orange

(-) blue

C

(W5/W26) 0 to 2315°C

1.9°C

6.1°C

ASTM

E988-90**

no

standard

no

standard

RTD Inputs:

Type: 3 or 4 wire, 2 wire can be compensated for lead wire resistance

Excitation current: 100 ohm range: 136.5 µA ±10%

10 ohm range: 2.05 mA ±10%

Lead resistance: 100 ohm range: 10 ohm/lead max.

10 ohm range: 3 ohms/lead max.

Max. continuous overload: 30 VDC

INPUT TYPE

RANGE

ACCURACY*

(18 to 28 °C)

ACCURACY*

(0 to 50 °C)

STANDARD

**

100 ohm Pt

alpha = .00385

-200 to 850°C

0.4°C

1.6°C

IEC 751

100 ohm Pt

alpha = .00392

-200 to 850°C

0.4°C

1.6°C

no official

standard

120 ohm Nickel

alpha = .00672

-80 to 259°C

0.2°C

0.5°C

no official

standard

10 ohm Copper

alpha = .00427

-110 to 260°C

0.4°C

0.9°C

no official

standard

Resistance Inputs:

INPUT

RANGE

ACCURACY *

(18 to 28°C)

ACCURACY *

(0 to 50°C) COMPLIANCE

MAX CONT.

OVERLOAD

RESOLUTION

100 ohm 0.05% of rdg

+0.03 ohm

0.2% of rdg

+0.04 ohm

0.175 V

30 V

0.1 ohm

999 ohm 0.05% of rdg

+0.3 ohm

0.2% of rdg

+0.4 ohm

1.75 V

30 V

1 ohm

9999 ohm 0.05% of rdg

+1 ohm

0.2% of rdg

+1.5 ohm

17.5 V

30 V

1 ohm

Higher resolution can be achieved via input scaling.

*

After 20 min. warm-up, @ 5 samples per second input rate. Accuracy is

specified in two ways: Accuracy over an 18 to 28ºC and 15 to 75% RH

environment; and Accuracy over a 0 to 50ºC and 0 to 85% RH (non

condensing) environment. The specification includes the A/D conversion

errors, linearization conformity, and thermocouple ice point compensation.

Total system accuracy is the sum of controller and probe errors. Accuracy

may be improved by field calibrating the controller readout at the

temperature of interest.

**

These curves have been corrected to ITS-90.