Colr, Unts, Adsp – Red Lion PAX2C User Manual
Page 22: Asgn, Lgic, Asel, 4 ( uann ), None, Sngl, Isplay
22
Univ Annun n
Default Color
Univ Annun n
Units
Mnemonic
P
D
dISP
2 O N E
F1
F2
P
D
Pro
N O
Pro
d I S P
2ONE
dSP
U A n n
Colr
UAn
G r n
UAnn
UAn
O N
Univ Annun n
Unit 1
Mnemonic
UAn1
UAn
0
Univ Annun n
Unit 2
Mnemonic
UAn2
UAn
1
Univ Annun n
Display Mode
AdSP
UAn
n o r
Univ Annun n
Assignment
ASGN
UAn
O u t 1
Advanced Menu Mode Only
Univ Annun n
Green
Backlight
Assignment
Univ Annun n
Orange
Backlight
Assignment
Univ Annun n
Red Backlight
Assignment
Univ Annun n
Green-Orange
Backlight
Assignment
Univ Annun n
Red-Orange
Backlight
Assignment
Univ Annun n
Red-Green
Backlight
Assignment
Grn
UAn
N O N E
OrNG
UAn
N O N E
rEd
UAn
N O N E
GnOr
UAn
N O N E
rdOr
UAn
N O N E
rdGn
UAn
N O N E
n
= UA Number (1 - 4)
UNIVERSAL ANNUNCIATOR n DISPLAY COLOR
Grn
OrNG
rEd
Enter the desired Universal Annunciator Display color.
Grn
= Green
OrNG
= Orange
rEd
= Red
UNIVERSAL ANNUNCIATOR n UNITS MNEMONIC
OFF
ON
This parameter allows programming of the display mnemonics
characters. Two individual characters may be selected from a
preprogrammed list.
The characters available for the programmable modes include:
A b C d E F G H I J K L M N O P Q R S t U V W Y Z 0 1
2 3 4 5 6 7 8 9
a c e g h i
m
n o q r u
w
- = [ ] / ° _ blank
UNIVERSAL ANNUNCIATOR n DISPLAY MODE
nor
rEv
FLSh
Enter the desired Universal Annunciator Display Mode. This
parameter is available when the Universal Annunciator is in List
(LISt) Mode.
nor
= Displays the configured universal annunciator
when the mapped parameter is activated (on).
rEv
= Displays the configured universal annunciator
when the mapped parameter is deactivated (off).
FLSh
= Flashes the configured universal annunciator
when the mapped parameter is activated (on).
UNIVERSAL ANNUNCIATOR n ASSIGNMENT
NONE Out1
Out2 Out3
Out4 ALr MAN
Selects the parameter that enables the Universal Annunciator
mnemonic to be displayed. If the mapped parameter is active, the
mnemonic is displayed. If the mapped parameter is not active, the
mnemonic will be disabled (off).
NONE
= Universal Annunciator text is disabled
Out1
= Output 1
Out2
= Output 2
Out3
= Output 3
Out4
= Output 4
ALr
= Alarm
MAN
= Manual Control Mode
The following programming steps are only available in the Advanced
Operating Mode.
These parameters allow Universal Annunciator n backlights to change color,
or alternate between two colors when the mapped parameter is activated. When
multiple backlight assignments are programmed for a particular zone, the color
priority is defined as follows (from Lowest to Highest): Grn, OrG, rEd, GnOr, rdOr,
rdGn
BACKLIGHT ASSIGNMENT SELECTIONS
NONE
= Backlight color change disabled
Out1
= Output 1
Out2
= Output 2
Out3
= Output 3
Out4
= Output 4
ALr
= Alarm
MAN
= Manual Control Mode
The following two programming steps are only available when the Backlight
Assignment is configured as an Alarm (Alr). These steps apply to each of the six
different backlight color assignment parameters.
ALARM LOGIC MODE
SNGL
And
Or
The PAX2C supports three different modes when an output is
assigned as an alarm:
SNGL
= Any single alarm
And
= Allows multiple alarms to be mapped to an output
using AND Boolean logic. For example: If AL1
and AL2 are active, the output will energize.
Or
= Allows multiple alarms to be mapped to an output
using OR Boolean logic. For example: If AL1 or
AL2 are active, the output will energize.
ALARM MASK ASSIGNMENT
NO
YES
Selects the alarms to be logically combined per the Alarm Logic
Mode selection. Any alarms configured as YES will be used in the
Boolean logic calculation. If the Alarm Logic Mode is assigned as
Single (SNGL), the last alarm selected as YES will be used.
Colr
UAn
rEd
UNtS
UAn
ON
Two character spaces are required to display this character.
AdSP
UAn
nor
ASGN
UAn
NONE
LGIC
UAn
SNGL
ASEL
UAn
NO
An
d
isplay
p
arameTers
: Z
One
C
OnfiguraTiOn
- u
niversal
a
nnunCiaTOrs
1-4 (UAnn)