beautypg.com

Selection/value entry, Programming mode exit, Programming tips – Red Lion PAX2C User Manual

Page 11: Inpt, Port, Disp, Slct, Numerical value entry

background image

11

F1

F2

F1

F2

F1

F2

F1

F2

F1

F2

F1

F2

D

P

D

P

D

Analog Input Setup

Parameters

User Input/Function Key

Parameters

D

D

D

Factory Service

Operations

Display Loop

2 seconds

Pro

N O

Pro

I N P t

Pro

N O

INPt

A n L G

INPt

U S E r

Pro

O u t

Pro

d I S P

F1

F2

P

D

Digital Output Setup

Parameters

Analog Output Setup

Parameters

Out

d G t L

Out

A n L G

F1

F2

D

Pro

P o r t

D

Pro

F A C t

Pro

E n d

F1

F2

P

D

USB Configuration

Parameters

Serial Communications

Parameters

Port

U S b

Port

S E r L

F1

F2

F1

F2

P

D

Display - General

Configuration Parameters

Display - Zone

Configuration Parameters

dISP

C N F G

dISP

Z O N E

F1

F2

Display - Line 2

Parameters

Display - Min/Max

Configuration Parameters

dISP

L O C S

dISP

H I L O

F1

F2

Display - Security Code

Configuration Parameters

dISP

C O d E

Pro

P i d

F1

F2

F1

F2

P

D

F1

F2

D

Pro

A L r

P

D

PID Control

Parameters

PID Setpoint

Parameters

Pid

C t r L

Pid

S P

F1

F2

PID

Parameters

Output Power

Parameters

Pid

P i d

Pid

P W r

F1

F2

On/Off

Parameters

Pid

O N O F

F1

F2

PID Tuning

Parameters

Pid

t u n E

Alarm

Parameters

SLCt

A L n

In Programming Menu:

Top line is green to indicate top level programming modules

Top line is orange to indicate module menu or sub-menu selection

Top line is red to indicate a changeable parameter.

SELECTION/VALUE ENTRY

For each parameter, the top line display shows the parameter while

the bottom line shows the selections/value for that parameter. The 

and  keys are used to move through the selections/values for the

parameter. Pressing the

P key, stores and activates the displayed

selection/value. This also advances the meter to the next parameter.

Numerical Value Entry

If the parameter is programmed for enter (Entr), the ! and @ keys

are used to change the parameter values in any of the display loops.

The ! and @ keys will increment or decrement the parameter value.

When the ! or @ key is pressed and held, the value automatically

scrolls. The longer the key is held the faster the value scrolls.

For large value changes, press and hold the ! or @ key. While

holding that key, momentarily press the opposite arrow key (@ or !)

to shift decades (10’s 100’s, etc), or momentarily press the

D key and

the value scrolls by 1000’s as the arrow key is held. Releasing the arrow

key removes the decade or 1000’s scroll feature. The arrow keys can

then be used to make small value changes as described above.

PROGRAMMING MODE EXIT

To exit the Programming Mode, press and hold the

D key (from

anywhere in the Programming Mode) or press the

P key with Pro NO

displayed. This will commit stored parameter changes to memory and

return the meter to the Display Mode. If a parameter was just changed,

the

P key must be pressed to store the change before pressing the D key.

(If power loss occurs before returning to the Display Mode, verify recent

parameter changes.)

PROGRAMMING TIPS

It is recommended to start with the Input Parameters and proceed

through each module in sequence. If lost or confused while programming,

press and hold the

D key to exit programming mode and start over. It is

recommended that program settings be recorded as programming is

performed. When programming is complete lock out programming with

a user input or lock-out code.

Factory Settings may be completely restored in the Factory Service

Operations module. This is useful when encountering programming

problems.