List, Alr ), Fnct ) – Red Lion PAX2C User Manual
Page 29: Disp, Locs, L o c s, D i s p, A l r, L o c, Line 2 user function accessible items
29
Line 2
Alarm n
Access
P
D
dISP
L O C S
F1
F2
P
D
Pro
N O
Pro
d I S P
LOCS
Ln2
A L r
ALn
Ln2
L O C
Line 2
Band n
Access
bdn
Ln2
L O C
d
isplay
p
arameTers
: l
ine
2 p
arameTer
v
alue
a
CCess
- a
larms
(ALr)
LINE 2 ALARM ACCESS
LOC
drEd
dEnt
PrEd
PEnt
HrEd
HEnt
When configured for dEnt, PEnt or HEnt, the Alarm n value can be
adjusted in the selected display loop by using the ! and @ keys
while viewing ALn. When configured for dEnt, the
P key must be
pressed to select the item prior to changing the value.
LINE 2 BAND/DEVIATION ACCESS
LOC
drEd
dEnt
PrEd
PEnt
HrEd
HEnt
When configured for dEnt, PEnt or HEnt, the Band/Deviation n
value can be adjusted in the selected display loop by using the ! and
@
keys while viewing bdn. When configured for dEnt, the
P key
must be pressed to select the item prior to changing the value.
ALn
Ln2
LOC
bdn
Ln2
LOC
Line 2
Setpoint Select
Access
P
D
dISP
L O C S
F1
F2
P
D
Pro
N O
Pro
d I S P
LOCS
Ln2
F N C t
SPSL
Ln2
L O C
Line 2
Manual/Auto
Access
trnF
Ln2
L O C
Line 2
PID Select
Access
PSEL
Ln2
L O C
Line 2
Setpoint
Ramping Access
SPrP
Ln2
L O C
Line 2
Integral Lock
Access
ILOC
Ln2
L O C
Line 2
Tuning Select
Access
tunE
Ln2
L O C
Line 2
Reset High
Access
r-HI
Ln2
L O C
Line 2
Reset Low
Access
r-Lo
Ln2
L O C
Line 2
Reset High-Low
Access
r-HL
Ln2
L O C
Line 2
Reset Alarm
Access
r-AL
Ln2
L O C
Line 2
List A/B
Access
LISt
Ln2
L O C
Line 2
Access
Prnt
Ln2
L O C
d
isplay
p
arameTers
: l
ine
2 u
ser
f
unCTiOn
a
CCess
- f
unCTiOns
(Fnct)
LINE 2 USER FUNCTION ACCESSIBLE ITEMS
The following list of User functions can be made available in the Display
(dEnt), Parameter (PEnt) or Hidden (HEnt) display loops. The more critical and
frequently used Functions should be first assigned to the User Inputs and User
Function keys. If more functions are needed than what can be obtained with
User Inputs, this feature will provide a means to provide that access. Please refer
to the USER INPUT / FUNCTION KEY PARAMETERS (USEr) section for a
detailed description of the available functions.
SPSL
ILOC
PSEL
r-HI
r-HL
LISt
*
SPrP
trnF
tunE
r-Lo
r-AL
Prnt
* Also available as a read-only item in the Display (
drEd
), Parameter (
PrEd
)
or Hidden (
HrEd
) Display loops.
LINE 2 PARAMETER LIST A/B ACCESS
LOC
drEd
dEnt
PrEd
PEnt
HrEd
HEnt
When configured for dEnt, PEnt or HEnt, the Parameter list can be
selected using a front keypad sequence. To select, push the
P key
while viewing LISt x”. “x” will begin to flash, press the ! key to
select “A” or “b” and then press
P key. The selected Parameter List
will become active and the display will advance to the next available item or
menu loop. See User Functions “Select Parameter List” for a description of the
list function. The Line 2 Parameter List provides a means of setting or viewing
the active parameter list.
LISt
Ln2
LOC
Basic Mode: 4 alarms max
Advanced Mode: 16 alarms max