Usrin3, Usr f1, Code – Red Lion C48T User Manual
Page 26: Usrin2, Usrin1, Scroll, Rstout print

User Input 1
User Input 1 can be programmed for any of the
parameters listed previously.
User Input 2
User Input 2 can be programmed for any of the
parameters listed previously, except for down timing.
User Input 3
User Input 3 can be programmed for any of the
parameters listed previously, except for down timing.
User F1 Key
User F1 is the front panel function key. This user input
can be programmed for any of the parameters listed
previously, except for the Program Disable and down
timing function.
-20-
Programming/Protected Parameter
Menu Code Value (0-199)
The Programming Code value can be used to provide
Data Value or Programming Menu security. Depending on
the Code range selected and the Program Disable Level, it
may be necessary to enter the code value before the unit
allows access to Programming Menus or Protected Values.
See Front Panel Accessible Functions With Program
Disable, page 11, for more information.
Scroll Display
This parameter configures whether or not the secondary
display will scroll or sequence automatically to the next
available value.
USrIn3
rSt. -L
USr F1
rSt. -L
CodE
0
USrIn2
rSt. -L
CODE VALUE DESCRIPTION
0
Programming is Disabled and Code entry
display is not available when Program is
Disabled.
1-99
Protected Parameter Menu appears when
Code is entered and Program is Disabled.
100-199
Programming Menu appears when code is
entered and Program is Disabled.
USrIn1
rSt. -L
ScroLL
no
MODE
DESCRIPTION
no
Disables or turns off display scrolling
YES
Enables display scrolling (2.5 Sec display time)
Reset Outputs (Edge Triggered); When the user input is activated,
all active outputs will reset to their inactive states. This is a
momentary reset.
Print Request [Level Active] (RS485 Option only); When the user
input is activated, the timer and preset values, as configured in the
Print Options (
PrnOPt
) parameter, will be continually transmitted on
the RS485 terminals. See RS485 Serial Communications, page 24.
rStOut
DESCRIPTION
MODE
Note 1: Only one user input may be programmed for a StorE or StrS
(Store&Reset) function.
Note 2: If the timer had previously stopped as a result of the timer Operating
mode (See Timer Operating Modes, page 13), it will restart following user
input release (level active reset modes) or immediately (edge triggered reset
modes).
C48t-im.QXD 3/5/04 3:29 PM Page 20