Paxd - u, Dc i, Paxp - p – Red Lion PAXT User Manual

Page 4: Odel, Niversal, Nput, Rocess, Paxd specifications, Paxp specifications

background image

4

m

Odel

paXd - U

niversal

dC i

npUT

m

Odel

paXp - p

rOCess

i

npUT

* After 20 minute warm-up. Accuracy is specified in two ways:

Accuracy over an 18 to 28°C and 10 to 75% RH environment; and

accuracy over a 0 to 50°C and 0 to 85% RH (non-condensing

environment). Accuracy over the 0 to 50°C range includes the

temperature coefficient effect of the meter.

EXCITATION POWER:

Transmitter Power: 24 VDC, ±5%, regulated, 50 mA max.

Reference Voltage: 2 VDC, ± 2%

Compliance: 1 kohm load min. (2 mA max.)

Temperature coefficient: 40 ppm/°C max.

Reference Current: 1.75 mADC, ± 2%

Compliance: 10 kohm load max.

Temperature coefficient: 40 ppm/°C max.

FOUR VOLTAGE RANGES (300 VDC Max)

FIVE CURRENT RANGES (2A DC Max)

THREE RESISTANCE RANGES (10K Ohm Max)

SELECTABLE 24 V, 2 V, 1.75 mA EXCITATION

DUAL RANGE INPUT (20 mA or 10 VDC)

24 VDC TRANSMITTER POWER

PAXD SPECIFICATIONS

INPUT RANGES:

PAXP SPECIFICATIONS

SENSOR INPUTS:

INPUT

RANGE

ACCURACY*

(18 to 28°C)

ACCURACY*

(0 to 50°C)

IMPEDANCE/

COMPLIANCE

MAX

CONTINUOUS

OVERLOAD

RESOLUTION

±

200 mVDC 0.03% of reading

+30 µV

0.12% of reading

+40 µV

1.066 Mohm

100 V

10 µV

±

2 VDC

0.03% of reading

+0.3 mV

0.12% of reading

+0.4 mV

1.066 Mohm

300 V

0.1 mV

±

20 VDC 0.03% of reading

+3 mV

0.12% of reading

+4 mV

1.066 Mohm

300 V

1 mV

±

300 VDC 0.05% of reading

+30 mV

0.15% of reading

+40 mV

1.066 Mohm

300 V

10 mV

±

200 µADC 0.03% of reading

+0.03 µA

0.12% of reading

+0.04µA

1.11 Kohm

15 mA

10 nA

±

2 mADC 0.03% of reading

+0.3 µA

0.12% of reading

+0.4 µA

111 ohm

50 mA

0.1 µA

±

20 mADC 0.03% of reading

+3µA

0.12% of reading

+4 µA

11.1 ohm

150 mA

1 µA

±

200 mADC 0.05% of reading

+30 µA

0.15% of reading

+40 µA

1.1 ohm

500 mA

10 µA

±

2 ADC

0.5% of reading

+0.3 mA

0.7% of reading

+0.4 mA

0.1 ohm

3 A

0.1 mA

100 ohm

0.05% of reading

+0.03 ohm

0.2% of reading

+0.04 ohm

0.175 V

30 V

0.01 ohm

1000 ohm 0.05% of reading

+0.3 ohm

0.2% of reading

+0.4 ohm

1.75 V

30 V

0.1 ohm

10 Kohm

0.05% of reading

+1 ohm

0.2% of reading

+1.5 ohm

17.5 V

30 V

1 ohm

* After 20 minute warm-up. Accuracy is specified in two ways: Accuracy over an 18

to 28°C and 10 to 75% RH environment; and accuracy over a 0 to 50°C and 0 to

85%RH (non-condensing environment). Accuracy over the 0 to 50°C range

includes the temperature coefficient effect of the meter.

EXCITATION POWER:

Transmitter Power: 24 VDC, ±5%, regulated, 50 mA max.

INPUT

(RANGE)

ACCURACY*

(18 to 28°C)

ACCURACY*

(0 to 50°C)

IMPEDANCE/

COMPLIANCE

MAX

CONTINUOUS

OVERLOAD

DISPLAY

RESOLUTION

20 mA

(-2 to 26 mA)

0.03% of

reading +2 µA

0.12% of

reading +3 µA

20 ohm

150 mA

1 µA

10 VDC

(-1 to 13 VDC)

0.03% of

reading +2 mV

0.12% of

reading +3 mV 500 Kohm

300 V

1 mV