6 module 6 - s, Etpoint, Larm – Red Lion PAXT User Manual
Page 23: Arameters, Parameter menu, Spt act-n, Spsel, Sp-n, Out-n hys-n, Ton-n

23
23
6-SPt
ACt-n
Setpoint
Select
SPSEL
Setpoint
Value
SP-n
Output
Logic
out-n
HYS-n
Setpoint
Hysteresis
tON-n
On Time
Delay
Off Time
Delay
tOF-n
Standby
Operation
Stb-n
Reset
Action
rSt-n
PAR
Pro
Burn-out
Action
brn-n
Setpoint
Action
LIt-n
Setpoint
Annunciators
PAXT
ONLY
6.6 mOdUle 6 - s
eTpOinT
(a
larm
) p
arameTers
(
) Ñ
PARAMETER MENU
Enter the setpoint (alarm output) to be programmed. The
in the following
parameters will reflect the chosen setpoint number. After the chosen setpoint is
completely programmed, the display will return to
. Repeat step for
each setpoint to be programmed. The
chosen at
will return to
.
The number of setpoints available is setpoint output card dependent.
SETPOINT SELECT
* Deviation and band action setpoints are relative to the value of setpoint 1.
It is not possible to configure setpoint 1 as deviation or band actions. It is
possible to use setpoint 1 for an absolute action, while its value is being used
for deviation or band.
** The lower Totalizer action
allows setpoints to function off of the
lower 5 digits of the Totalizer. The upper Totalizer action
allows
setpoints to function off of the upper 4 digits of the Totalizer. To obtain
absolute low alarms for the Totalizer, program the
or
output
logic as reverse.
Enter the action for the selected setpoint (alarm output). See Setpoint Alarm
Figures for a visual detail of each action.
SETPOINT ACTION
=
Absolute high, with balanced hysteresis
Absolute low, with balanced hysteresis
Absolute high, with unbalanced hysteresis
Absolute low, with unbalanced hysteresis
Deviation low, with unbalanced hysteresis *
=
Outside band, with unbalanced hysteresis *
Upper Totalizer absolute high, unbalance hysteresis**
=
=
=
=
=
=
=
=
Setpoint always off, (returns to SPSEL NO)
Deviation high, with unbalanced hysteresis *
Lower Totalizer absolute high, unbalance hysteresis**
Setpoint Alarm Figures
With reverse output logic
, the below alarm states are opposite.
ALARM
STATE
OFF
ON
Hys
SP + Hys
SP
OFF
TRIGGER POINTS
ALARM
STATE
ON
OFF
Hys
SP1 + (-SPn)
SP1
ON
TRIGGER POINTS
Absolute Low Acting (Unbalanced Hys) =
Deviation High Acting (SP
< 0) =
ALARM
STATE
OFF
ON
Hys
SP + ½Hys
SP
SP - ½Hys
OFF
TRIGGER POINTS
ALARM
STATE
OFF
ON
Hys
SP1 + SPn
SP1
OFF
TRIGGER POINTS
ALARM
STATE
ON
OFF
Hys
SP1 - (-SPn)
SP1
ON
TRIGGER POINTS
Absolute Low Acting (Balanced Hys) =
Deviation High Acting (SP
> 0) =
Deviation Low Acting (SP
< 0)=
ALARM
STATE
OFF
ON
Hys
SP
SP - Hys
OFF
TRIGGER POINTS
ALARM
STATE
OFF
ON
Hys
SP1 - SPn
SP1
OFF
TRIGGER POINTS
ALARM
STATE
OFF
ON
Hys
SP1 - SPn
SP1
OFF
SP1 + SPn
ON
OFF
Hys
TRIGGER POINTS
Absolute High Acting (Unbalanced Hys) =
This is also for Totalizer alarms:
,
Deviation Low Acting (SP > 0) =
Band Outside Acting =
ALARM
STATE
OFF
ON
Hys
SP + ½Hys
SP
SP - ½Hys
OFF
TRIGGER POINTS
Absolute High Acting (Balanced Hys) =
Depending on the card installed, there will be two or four setpoint outputs
available. For maximum input frequency, unused Setpoints should be configured
for
action.
The setpoint assignment and the setpoint action determine certain setpoint
feature availability.
Ñ
- A setpoint card must be installed in order to access this module.