Diagnostic commands
The PTU200 series digital transmitters respond to a set of diagnostic
commands, which are useful for analyzing the basic settings and
general operation of the transmitters. The diagnostic commands are
listed in
T
ABLE
7-2
Diagnostic commands
Function
Command
basic information on settings
?
software version
VERS
serial number
SNUM
outputting error messages
ERRS
? Basic information on the transmitter settings
?
The ? command lists the basic information of the transmitter.
>?
Software version
PTU200 / 1.02
Serial number
T5030004
Configuration
12
Linear adjustments
ON
Multipoint adjustments
ON
Calibration date
1999-03-12
Baud Parity Data Stop Dpx 9600
E 7 1 F
Echo
ON
Sending mode
STOP
Address
0
Output interval
3 s
Output format
4.1 P " " UUU " " 2.1 RH " " UUU #r #n
Error output format
SCOM format
Pressure unit
hPa
Temperature unit
'C
Transducer 1:
TYPE: PMT
Transducer 2:
TYPE: VMT
Transducer 3:
TYPE: NONE
>
NOTE
Use this command only for one transmitter at a time. Any PTU200
series transmitter will always respond to ?-command whatever its
settings are, provided that the serial interface settings are correct.