Send outputting a single message only, Reset resetting the transmitter, Poll mode – Vaisala PTU200 User Manual
Page 31
C
HAPTER
5________________________________________________________________
OPERATING
V
AISALA
_________________________________________________________________________ 27
SEND Outputting a single message only
SEND
This command is used to output one message at a time in the STOP
and RUN modes.
>reset
PTU200 / 1.01
>send
1013.25 hPa 22.9 %RH 22.4 'C
>
The user may also use his own one-message command if he has
previously specified one using the SCOM command (see Chapter on
page 11).
RESET Resetting the transmitter
RESET
The RESET command is used to reset the transmitter. All software
settings remain in the memory after reset or any power failure. The
RESET command must always be given if the serial bus settings, DIP
switch settings or the operating mode of the transmitter have been
changed.
Example:
>reset
PTU200 / 1.01
>
POLL mode
T
ABLE
5-2
Commands used in RUN and STOP modes
Function
Command
single message output
SEND
opening a transmitter
OPEN
closing a transmitter
CLOSE