Definitions
The following is a list of initials, terms, and definitions used with this product.
Table 13 Terms and Definitions
Term Definition
AC
Alternating Current; refers to voltage produced by the inverter, utility grid, or generator
AGS
Advanced Generator Start
AUX
Inverter’s 12-volt auxiliary output
AXS Card
Optional Modbus Ethernet accessory for the FLEXmax Extreme
CE
Conformité Européenne; French for “European Conformity”; a marking on OutBack products
indicating that they meet European Union requirements
DC
Direct Current; refers to voltage produced by the batteries or renewable source
Derate
Automatic reduction of the FLEXmax Extreme rated output of 80 Adc; usually performed for
temperature reasons
DVM Digital
Voltmeter
EMI
Electromagnetic Interference; a detrimental condition that affects electronic circuits
EPO
Emergency Power Off; a manual switch intended to disconnect power on short notice
FET
Field Effect Transistor; a reference to a temperature reading by the FLEXmax Extreme
FN-DC
FLEXnet DC; the OutBack Battery Monitor
GFDI
Ground Fault Detector/Interruptor; shuts down the system if a ground fault event occurs
Grid-interactive,
grid-tie
Utility grid power is available for use and the system is capable of returning (selling) electricity
back to the utility grid
Ground Fault
An unsafe condition of current flow to ground, resulting from accidental contact between an
electrical source and ground
I
mp
Maximum-power current; the current harvested by MPPT when operating at the V
mp
I
sc
Short-circuit current; the fully-loaded current displayed by a PV module or array
LED Light-Emitting
Diode;
refers
to indicators used by the FLEXmax Extreme and the system display
MPP, MPPT
Maximum Power Point, Maximum Power Point Tracking
Negative-Ground
A wiring system that bonds the negative conductor to ground for safety
Network
OutBack devices which communicate on a bus established by the HUB Communications Manager
Positive-Ground
A wiring system that bonds the positive conductor to ground for safety