Specifications

66

900-0150-01-00 Rev A

Default Settings and Ranges

The settings in this table are as displayed in the MATE3 system display for a 12-volt system.

Table 10 FLEXmax Settings (MATE3)

Mode

Menu Item

Setting

Charger

Absorb Voltage

Default 14.4 Vdc

Range: Float setting to 80 Vdc

(Absorb) Time

Default 01.0 hours Range: 00.0 to 24 hours

Float

Default 13.8 Vdc

Range: 12.0 Vdc to Absorbing setting

Rebulk Voltage

Default 12.0 Vdc

Range: 12.0 Vdc to Float setting

Current Limit

Default 80 Adc

Range: 5 to 80 Adc

Absorb End Amps

Default 00 Adc

Range: 00 to 55 Adc

MPPT

MPPT Mode

Default

or U-Pick>

U-Pick VOC

Default 77% Voc

Range: 40 to 90% Voc

Wakeup VOC Change

Default 1.5 Vdc

Range: 1.5 to 9.5 Vdc

(Wakeup VOC) Time

Default 05 minutes

Range: 05 to 15 minutes

Snooze Mode Amps

Default 0.6 Adc

Range: 0.2 to 1.0 Adc

MPP Range Minimum

Default <Half>

(MPP Range) Maximum

Default <90%>

<80, 85, 90, 99%>

Temperature
Compensation

Mode

Default

or

Slope

Default 5 mV

Range: 2 to 6 mV

Lower Battery Voltage

Default 14.1 Vdc

Range: 10 Vdc to Upper Battery Voltage setting

Upper Battery Voltage

Default 14.1 Vdc

Range: Lower Voltage setting to 80 Vdc

Battery Equalize

Equalization Voltage

Default 14.4 Vdc

Range: Absorb Voltage setting to 80 Vdc

(Equalization) Hours

Default 01 hours

Range: 1 to 7 hours

Automatic Battery Equalization

Default 0 days

Range: 0 to 250 days

Grid-Tie Mode

Enable Grid-Tie Mode

Default N

Range: Y or N

Auxiliary Output

Diversion:Relay

Default

Active

Default Active High

Range: Active High or Active Low

Relative

Voltage

Default 0.0 Vdc

Range: 0.0 to 5.0 Vdc

Hysteresis

Default 00.2 Vdc

Range: 0.0 to12.0 Vdc

Hold

Default 0.1 second

Range: 0.0 to 25 seconds

Delay

Default 0.0 seconds

Range: 0.0 to 24 seconds