beautypg.com

Operation, Silent, Figure 25 – Outback Power Systems FLEXmax Extreme Owners Manual User Manual

Page 30: Led indicators (fault), Table 4 reasons for silent mode

background image

Operation

28

900-0150-01-00 Rev A

Silent

The MATE3 displays the operating mode as Silent if the charge controller has stopped charging. This message
represents a variety of conditions, many of which are common. For example, Silent is shown at night or any
period of insufficient light. Table 4 lists the indicators and the PV open-circuit voltage which show specific Silent
conditions. In these cases, no indicators will be illuminated.

However, Silent may also appear in the event of an error shutdown. If the mode is Silent and the red Fault
indicator is illuminated, an External Fault may have occurred. See pages 19, 20, and 61.

Figure 25

LED Indicators (Fault)

Table 4

Reasons for Silent Mode

Charge LED

Status LED

Fault LED

V

oc

Other

No No

No

Below battery

No PV energy or “Sleep” mode. If the V

oc

is less than

battery voltage, the controller is “sleeping”. This is
normal at night. The threshold for Sleep mode is
settable. See page 37.

Above battery

Low light or “Snooze” mode. V

oc

is greater than battery

voltage but not enough array current is available for
charging. This is normal in the morning, evening, or in
heavy clouds (low light). The threshold for Snooze
mode is settable. See page 37.

Intermittent Any

No

Above

battery

“Wakeup” mode. The controller has detected more than
the required 10 watts, but has not yet begun charging.
This condition only lasts a short time. The blue Charge
indicator may turn on and off briefly while the controller
is performing initial power tracking. This can also occur
if PV conditions change and the controller has to
calculate a new power point.

If continuous, this behavior may also indicate an
“unloaded output” condition where the batteries have
been disconnected from the charge controller.

Red (solid)