beautypg.com

C.33 – HP 3PAR Application Software Suite for Microsoft Exchange User Manual

Page 143

background image

C.33

Description of Events

3PAR Recovery Manager 4.1.0 For Microsoft Exchange 2010 User’s Guide

5106

RME5106: ERROR: The VSS

Writer is not responding.

The VSS Writer is not

responding.

Run

vssadmin list

writers

to verify that the

VSS writer is in a healthy

state.

5108

RME5108: ERROR: The VSS

Writer infrastructure is not

operating properly. Check

that the Event Service and

VSS have been started, and

check for errors associated

with those services in the

error log.

The VSS Writer is not

operating properly.

Check that the Event Service

and VSS have been started.

Run

vssadmin list

writers

to verify that the

VSS writer is in a healthy

state and check the system

event log for errors

associated with those

services.

5111

RME5111: ERROR: The 3PAR

VSS Provider is not registered

on this computer.

A registered version of VSS

Provider was not detected.

Check that 3PAR VSS

Provider is properly installed

on the system.

Run

vssadmin list

providers

to verify that

3PAR VSS provider is

properly registered.

If you cannot resolve the

problem, uninstall the 3PAR

VSS Provider package and

install it again.

Table C-1. Recovery Manager for Microsoft Exchange Event Messages (continued)

Event ID

Error Message

Description/Action