C.32

Description of Events

3PAR Recovery Manager 4.1.0 For Microsoft Exchange 2010 User’s Guide

5102

RME5102: ERROR: The VSS

Writer ran out of memory or

other system resources. The

recommended way to handle

this error is to wait ten

minutes and then repeat the

operation. If the VSS Writer is

in a bad state, restart the

writer’s service. Check the

application event log.

A resource allocation error

has occurred during a VSS

Writer operation.

Try waiting 10 minutes and

then retry the operation.

Run

vssadmin list

writers

to verify that the

VSS writer is in Healthy state.

5103

RME5103: ERROR: The VSS

Writer operation failed

because of a time-out

between the Freeze and

Thaw events.

The VSS Writer operation has

exceeded the 20 second time-

out limit for the freeze and

thaw stage allocated by

Exchange.

Verify that the Exchange

writer is in a healthy state

using

vssadmin list

writers

.

5104

RME5104: ERROR: The VSS

Exchange Writer has failed.

This can be verified by

running the command

"vssadmin list writers" from

the command line. To put it

into a stable state and to

continue creating snapshots,

restart the Microsoft

Exchange information store.

The VSS Exchange Writer has

failed.

This can be verified by

running the

vssadmin

list writers

command

from the command line.

You may need to restart the

VSS service and/or Exchange

Information Store service.

Table C-1. Recovery Manager for Microsoft Exchange Event Messages (continued)

Event ID