A-4 Troubleshooting

Normal Conditions

The Power LED is controlled by hardware and is always on
when power is connected. See the following table to interpret the
state of other LEDs.

* The Network LED will flash when there is network traffic.

Error Conditions

The following table shows how the front panel indicators show
various error conditions:

* The Network LED will flash when there is network traffic.
** Check the stat.txt file in the server’s config folder for more information.
*** The CD LED and Network LED flash alternately in this condition.

Event

Status
LED

CD
LED

Network
LED

Initial power to unit

ON

ON

ON

During power-up/Self-test.
Approx. 30 seconds.

Flash

OFF

OFF

After power-up/Self-test

OFF

OFF

Flash*

First disc inserted

OFF

ON

Flash*

Last disc removed

OFF

OFF

Flash*

Flash loading

1 Flash/sec

1 Flash/sec

1 Flash/sec

Event

Status
LED

CD
LED

Network
LED

CD-ROM has incorrect format or
SCSI bus not connected**

OFF

Flash

Flash*

Faulty network connection

OFF

N/A

OFF

Illegal LAN hardware address.

Flash

Flash

Flash

Flash load failed

Flash

OFF

OFF

Error in EEPROM

Flash

OFF

OFF

Error in FLASH PROM

Flash

OFF

Flash

Error in SRAM

Flash

Flash

OFF

Error in DRAM/DIMM

Flash

OFF

OFF

Error in DRAM/DIMM
configuration error

Flash

Flash

OFF

Software/Hardware
combination error

Flash

Flash***

Flash***

hp.book Page 4 Thursday, April 2, 1998 4:33 PM