HP Surestore NAS User Manual
Page 80
A-4 Troubleshooting
Normal Conditions
The Power LED is controlled by hardware and is always on
when power is connected. See the following table to interpret the
state of other LEDs.
* The Network LED will flash when there is network traffic.
Error Conditions
The following table shows how the front panel indicators show
various error conditions:
* The Network LED will flash when there is network traffic.
** Check the stat.txt file in the server’s config folder for more information.
*** The CD LED and Network LED flash alternately in this condition.
Event
Status
LED
CD
LED
Network
LED
Initial power to unit
ON
ON
ON
During power-up/Self-test.
Approx. 30 seconds.
Flash
OFF
OFF
After power-up/Self-test
OFF
OFF
Flash*
First disc inserted
OFF
ON
Flash*
Last disc removed
OFF
OFF
Flash*
Flash loading
1 Flash/sec
1 Flash/sec
1 Flash/sec
Event
Status
LED
CD
LED
Network
LED
CD-ROM has incorrect format or
SCSI bus not connected**
OFF
Flash
Flash*
Faulty network connection
OFF
N/A
OFF
Illegal LAN hardware address.
Flash
Flash
Flash
Flash load failed
Flash
OFF
OFF
Error in EEPROM
Flash
OFF
OFF
Error in FLASH PROM
Flash
OFF
Flash
Error in SRAM
Flash
Flash
OFF
Error in DRAM/DIMM
Flash
OFF
OFF
Error in DRAM/DIMM
configuration error
Flash
Flash
OFF
Software/Hardware
combination error
Flash
Flash***
Flash***
hp.book Page 4 Thursday, April 2, 1998 4:33 PM