Temperature error conditions, Blower error conditions, Temperature sensor element numbers – HP StorageWorks 2500 Disk System User Manual
Page 80

Table 23 Blower error conditions
Error
condition
Severity
Description
Actions
0.3.en.03
Unrecoverable
Blower en has stopped.
0.3.en.04
Unrecoverable
Power supply en has detected an
internal blower error.
0.3.en.05
Noncritical
Blower en is missing or is improperly
installed.
Replace the blower as soon as
possible.
0.3.en.06
Unrecoverable
No blowers are installed.
Enclosure shutdown is imminent.
When this condition exists there will be
two error messages:
•
0.3.en.05 identifies the first blower
•
0.3.en.06 identifies the second
blower
The EMU will shut down the
enclosure in 7 minutes unless
you install blowers.
Temperature error conditions
The format of a temperature sensor condition report is 0.4.en.ec, where:
•
0.4. identifies a temperature sensor error.
•
en. identifies the location of the affected temperature sensor.
•
ec provides details about the error.
See
to determine the location of each temperature sensor.
Table 24 Temperature sensor element numbers
Element number
(en.)
Sensor location
Element number
(en.)
Sensor location
01.
Power supply 1
10.
Drive bay 7
02.
Power supply 2
11.
Drive bay 8
03.
EMU
12.
Drive bay 9
04.
Drive bay 1
13.
Drive bay 10
05.
Drive bay 2
14.
Drive bay 11
06.
Drive bay 3
15.
Drive bay 12
07.
Drive bay 4
16.
Drive bay 13
08.
Drive bay 5
17.
Drive bay 14
09.
Drive bay 6
80
EMU-generated error condition reports