C EMU-generated error condition

reports

Error condition report format

When the EMU alphanumeric display is Er, three sub-levels of information provide details about the error

condition: the element or component type, the specific component, and the error code. You can use

this information to determine the probable cause of the problem.

The first sub-level displays the element type (et), which identifies the type of component affected.

See

Table 20

to decipher the element type code.

The second sub-level displays the element number (en), which identifies the exact component

affected.

The third sub-level display provides an error code (ec), which defines a specific problem.

NOTE:

The conventions used to differentiate between the bytes of the condition report are:
• Element type—Period after each character (0.1.)
• Element number—Period after the second character (01.)
• Error code—No periods (01)

Table 20

lists the element type codes assigned to the DS2500 components.

Table 20 Element type

Element type (et)

Component

0.1.

Disk drive

0.2.

Power supply

0.3.

Blower

0.4.

Temperature sensor

0.6

Audible alarm

1

0.7.

EMU

0.F.

Transceivers

1.0.

Language

1

1.1.

Communication port

1

1.2.

Voltage sensor

1.3

Current sensor

8.0

DS2500 enclosure

1

8.2.

DS2500 backplane

8.7.

I/O module

1

Does not generate a condition report. However, for any error, you should record the error code. Then, implement

the recommended corrective action.

2500 Disk System user guide

77