Correcting error conditions

Correcting an error may require you to perform a specific set of actions. Your authorized-HP service

representative can help you determine the corrective action to take.

Disk drive error conditions

The format of a disk drive error condition report is 0.1.en.ec, where:

0.1. identifies a disk problem.

en. identifies the affected disk drive bay number.
A direct correlation exists between the disk drive element number and the bay number.
The bays are numbered sequentially 1 through 14 from left to right.

ec is the error code.

Table 21 Disk drive error conditions

Error

condition

Severity

Description

Actions

0.1.en.01

Critical

Drive configuration or drive link rate

error:
The drive in bay en is either not

FC-compatible or is unable to operate

at the link rate established by the I/O

module.

1.

If the drive is not

FC-compatible, replace it

with a FC-compatible drive or

a drive blank.

2.

Replace the drive with a FC

drive capable of operating at

a link rate established by the

I/O module.

0.1.en.02

Information

Drive is missing from bay en.

1.

If the bay is empty, install a

drive or a drive blank.

2.

Reseat the drive to ensure that

it is properly installed.

3.

Install a replacement drive or

drive blank.

0.1.en.03

Information

Drive removed after the HP-UX software

activated the drive lock.

Unlock the drive using HP-UX

software.

0.1.en.04

Critical

Loop A drive link rate incorrect.
The drive in bay en is capable

of operating at the loop link rate

established by I/O module A, but is

running at a different rate.

1.

Reseat the drive to ensure that

it is properly installed.

2.

Replace the drive.

0.1.en.05

Critical

Loop B drive link rate incorrect.
The drive in bay en is capable

of operating at the loop link rate

established by I/O module B, but is

running at a different rate.

1.

Reseat the drive to ensure that

it is properly installed.

2.

Replace the drive.

Power supply error conditions

The format of a power supply error condition report is 0.2.en.ec, where:

0.2. identifies a power supply error.

en. identifies which power supply is affected

78

EMU-generated error condition reports